7. AD DATA CHECK
This menu is used to display the A/D conversion value
of the main CPU which detects panel keys of the main
unit and protection functions in % using the sub-menu.
During signal processing, the condition before
execution is maintained.
* The figures in the diagram are given as reference
only.
7. AD DATA CHECK
本体パネルキー、プロテクションなどを検出しているメ
インCPUのA/D変換の値を、サブメニューで%表示しま
す。信号処理は実行前の状態を維持します。
※図中の数値は参考例です。
PS (Power supply voltage protection detection)
PS: Power supply voltage protection value (Normal
value: PS: 52 to 86)
* If PS is out of the normal value range, the protection
function works to turn off the power.
(Reference voltage: 3.3V=100%)
PS (電源電圧プロテクションの検出)
PS: 電源電圧プロテクションの値(正常値:52∼86)
PSは正常値を外れるとプロテクションが働き、電源オ
フされます。
(基準電圧:3.3V=100%)
K0/K1 (Panel key of main unit) [Remote control code: –]
A/D of the key fails to function properly when the standard
value is deviated by ±4%. In this case, check the constant
of partial pressure resistor, solder condition, etc. Refer to
table 2.
(Reference voltage: 3.3V=100%)
K0/K1 (本体パネルキー)
キーのA/Dは基準値から±4%を外れると、正常な動きをし
ません。下表2をご覧になり、各キーの分圧抵抗の定数、
ハンダ不良等の確認をしてください。
(基準電圧:3.3V=100%)
[Table 2 / 表2]
Display
0+2
10±2
100-2
K0
VOLUME +
INPUT
NO KEY
K1
VOLUME -
NO KEY
8. VC STATUS
Not applied to this model.
8. VC STATUS
このモデルには適用されません。
LOW BYTE DATA
Not applied to this model.
LOW BYTE DATA
このモデルには適用されません。
HIGH BYTE DATA
Not applied to this model.
HIGH BYTE DATA
このモデルには適用されません。