Series No: 2017-09-00010 Battery UN38.3 Test Report Model: YBP-S01 (3.6Vdc==2100mAh/7.56Wh) PN: 541389220001 Date: 2017/09/21 GETAC TECHNOLOGY(Kun shan) LTD No.269 2nd road export processing zone changjiang south road,Jangsu P.R.C.
•Reference to assembled battery testing requirements and testing results: NO UN Manual of Tests and TEST TIME RESULT 2017/9/7 PASS Criteria 1 Altitude simulation 2 Thermal test 2017/9/8~2017/9/14 PASS 3 Vibration 2017/9/15~2017/9/18 PASS 4 Shock 2017/9/19 PASS 5 External short circuit 2017/9/20 PASS 6 Impact 2017/9/7~2017/9/9 PASS 7 Overcharge 2017/9/7~2017/9/15 PASS 8 Forced discharge 2017/9/11~2017/9/18 PASS • Reference to revised edition of the UN Manual of Tests and C
Remark: Rechargeable single cell batteries: Sample #1~#10 ten single cell batteries, at first cycle, in fully charge states; Sample #11~#14 four single cell batteries, at first cycle, in fully charge states; Sample #15~#18 four single cell batteries, after fifty cycles ending in fully charge states; Component Cell #1~#5 five cells, at first cycle, at 50% of design rate capacity; Component Cell #6~#15 ten cells, at first cycle, in fully discharged states; Component Cell #16~#25 ten cells, after fifty cycles
1. Altitude simulation 1. Test Equipment: BE-DY-27/1170001, KEITHLEY2700/0280002, KDB-1200/0040026 2. Purpose: This test simulates air transport under low-pressure condition. 3. Test Conditions: Test batteries shall be stored at a pressure of 11.6 kPa or less for at least six hours at ambient temperature (20±5 °C). 4.
KEITHLEY2700/0280002, KDB-1200/0040026 2. Purpose: This test assesses battery seal integrity and internal electrical connections. The test is conducted using rapid and extreme temperature change. 3. Test Conditions: Test batteries are to be stored for at least six hours at a test temperature equal to 72 ± 2 °C, followed by storage for at least six hours at a test temperature equal to – 40 ± 2 °C. The maximum time interval between test temperature extremes is 30 minutes.
2. Purpose: This test simulates vibration during transport. 3. Test Conditions: Batteries are firmly secured to the platform of the vibration machine without distorting the cell such a manner as to faithfully transmit the vibration. The vibration shall be a sinusoidal waveform with algorithmic sweep between 7 Hz and 200 Hz and back to 7 Hz traversed in 15 minutes. This cycle shall be repeated 12 times for a total of 3 hours for each of three mutually perpendicular mounting positions of the cell.
4. Shock 1. Test Equipment: ASQ-700/0900001, KEITHLEY2700/0280002, KDB-1200/0040026 2. Purpose: This test assesses the robustness of batteries against cumulative shocks. 3. Test Conditions: Test batteries shall be secured to the testing machine by means of a rigid mount which will support all mounting surfaces of each test battery. Each battery shall be subjected to a half-sine shock of peak acceleration depending on the mass of the battery. The pulse duration shall be 6 milliseconds for small batteries.
Each battery shall be subjected to three shocks in the positive direction and to three shocks in the negative direction in each of three mutually perpendicular mounting positions of the battery for a total of 18 shocks. 4. Requirement: Batteries meet this requirement if there is no leakage, no venting, no disassembly, no rupture and no fire and if the open circuit voltage of each test battery after testing is not less than 90% of its voltage immediately prior to this procedure.
#8 4.123 47.04 4.122 47.04 0.00 99.98 OK #9 4.124 46.93 4.123 46.93 0.00 99.98 OK #10 4.121 47.00 4.120 47.00 0.00 99.98 OK Note: OK- No Leakage, No Venting, No Disassembly, No rupture & No Fire; NG- Leakage, Venting, Disassembly, rupture & Fire. 6. Test result: PASS 5. External short circuit 1. Test Equipment: MHU-225Q/0120004, GX-3000-150LTC2/01300031, KEITHLEY2700+7700/0280003 2. Purpose: This test simulates an external short circuit. 3.
#9 56.6 OK #10 56.5 OK Note: OK- No Disassembly, No rupture & No Fire; NG- Disassembly, rupture & Fire. 6. Test result: PASS 6. Impact 1. Test Equipment: BE-6048/1180001, KEITHLEY2700+7700/0280003 2. Purpose: These tests simulate mechanical abuse from an impact that may result in an internal short circuit. 3. Test Conditions: Test procedure – Impact (applicable to cylindrical cells not less than 18.0 mm in diameter) The sample cell or component cell is to be placed on a flat smooth surface. A 15.
6. Test result: PASS 7. Overcharge 1. Test Equipment: ITECH IT6952A 60V/25A/600W/0020243~0020250 2. Purpose: This test evaluates the ability of a rechargeable battery to withstand an overcharge condition. 3. Test Conditions: The charge current shall be twice the manufacturer's recommended maximum continuous charge current.
6. Test result: PASS 8. Forced discharge 1. Test Equipment: ITECH IT6952A 60V/25A/600W/0020243~0020250 Chroma 63103/0230171/0230172/0230175/0230176 Chroma 63102/0230173/0230174/0230177/0230178 2. Purpose: This test evaluates the ability of a rechargeable cell to withstand a forced discharge condition. 3. Test Conditions: Each cell shall be forced discharged at ambient temperature by connecting it in series with a 12V D.C.
#16 OK #17 OK #18 OK #19 OK #20 OK #21 OK #22 OK #23 OK #24 OK #25 OK Note: OK- No Disassembly & No Fire; NG- Disassembly & Fire. 6.
*Product Manufacturer: Company Name: Getac Technology (Kun Shan) LTD. Address: No.269, 2nd export processing zone changjiang south road,Jangsu P.R.C. Telephone Number: +86-512-5736-7777 Email Address: Getac-PPBU@getac.com Website: https://power.getac.com/ *Test Laboratory: Company Name: Getac Technology (Kun Shan) LTD. Address: No.269 2nd road export processing zone changjiang south road,Jangsu P.R.C. Website: https://power.getac.com/ Email Address: Getac-PPBU@getac.