Service manual

ELEC
8-6
EAS00775 EAS00754
7. Charging coil resistance
Disconnect the charging coil coupler from
the wire harness.
Connect the pocket tester ( × 100) to the
charging coil terminal as shown.
Positive tester probe black / red
Negative tester probe green / white
Measure the charging coil resistance.
Charging coil resistance
720 ~ 1,080 at 20 °C (68 °F)
Connect the pocket tester ( × 10) to the
charging coil
Positive tester probe green / blue
Negative tester probe black
Measure the charging coil resistance.
Charging coil resistance
44 ~ 66 at 20 °C (68 °F)
Is the charging coil OK?
YES
NO
Replace the charg-
ing coil.
8. Wiring
Check the entire ignition system’s wiring.
Refer to “WIRING DIAGRAM”.
Is the ignition system’s wiring properly con-
nected and without defects?
YES
NO
Replace the CDI
unit.
Properly connect or
repair the ignition
system’s wiring.
IGNITION SYSTEM