Assembly Manual

34
ForsquarenessmaintainFlushand3/4"
measurementalongpaneledges.
BACK WALL PANELS
48 x 84"
(121,9 x 213,4 cm)
PARTSREQUIRED:
x1
x45
2" (5,1 cm)
Fig.B
BEGINHERE
Fig.A
3/4"
(1,9 cm)
3/4"
(1,9 cm)
2Nails
2Nails
Flush
48"
(121,9 cm)
3/4"
(1,9 cm)
1”
(2,5 cm)
3/4"
(1,9 cm)
12"
(30,5 cm)
6"
(15,2 cm)
Place 48x84" panel onto wall frame ush to top of frame with primed side up as shown.
Use the gauge block to mark the 3/4" measurement on the wall stud. Secure panel with
two 2" nails in the corners (Fig.A).
Nail the panel using 2" nails 6" apart on edges and 12" apart inside panel.
Ensureyourwallframeissquarebyinstallingonepanelandsquaringframe.
Move to the opposite end. Using the long edge of the panel as a lever move the panel side-to-side until you have
a 3/4" measurement on the wall stud. Secure corner with two 2" nails (Fig.B).
4
5
3
3/4"GAUGE
BLOCK
GAA
3/4"GAUGE
BLOCK
Primed
side up