63
HINT: Ensure window cutouts align with OSB panel cutouts.
4-5/16"
(11 cm)
PARTSREQUIRED:
DORMER OUTER WALL PANELS
x10
3/4" (1,9 cm)
2" (5,1 cm)
x50
BEGIN
¸
1
Align 16-3/4"x72"front panel ush with OSB window openings (Fig.A)and ush at sides(Fig.B).
Secure with 2" nails into front dormer frame as shown. Space nails 6" apart along edges.
Place right side 16-11/16"x58"panel ush along top of OSB side panel. Ensure 16-11/16"x58" side panel
is ush with front edge of 16-3/4"x72"front panel (Fig.C). Secure with (8) 2" nails into through side OSB
panel into dormer side frame. Space nails evenly.
2
x1
3/8 x 16-11/16 x 58"
(1,1 x 42,4 x 147,3 cm)
x1
3/8 x 16-11/16 x 58"
(1,1 x 42,4 x 147,3 cm)
x1
3/8 x 16-3/4 x 72"
(1,1 x 42,5 x 182,9 cm)
6"
(15,2 cm)
Flush
Flush
16-3/4"x72"
2"(5,1cm)
Nails
2"(5,1cm)
Nails
Fig.B
Flush
Fig.C
Flush
Flush
Flush
Flush
16-11/16"x58"
16-11/16"x58"