Specifications

YASKAWA Inverter Drive A1000 – Crane Software Application Manual
13
Access Level <1>
No. Parameter Name
Setting
Range
Units Default Description
During
Run
V/f
V/f
with PG
OLV CLV
MEMOBUS
Address
d7-01 Offset Frequency 1
-100.0
to
100.0
0.1% 0.0
Added to the frequency reference if the digital
input Offset Frequency 1 is enabled.
A A A A 2B2H
d7-02 Offset Frequency 2
-100.0
to
100.0
0.1% 0.0
Added to the frequency reference if the digital
input Offset Frequency 2 is enabled.
A A A A 2B3H
Offset Frequency
d7-03 Offset Frequency 3
-100.0
to
100.0
0.1% 0.0
Added to the frequency reference if the digital
input Offset Frequency 3 is enabled.
A A A A 2B4H
E1-01 Input Voltage Setting
155 to
255
<7>
1 VAC
200
<7>
Drive Input Voltage Q,A Q,A Q,A Q,A 300H
E1-03 V/f Pattern Selection 0 to FF - F
0 – E: Select from 15 preset fixed
patterns. See section 5.5 of the A1000
standard drive technical manual (SIEP
C710616 27
) for further details.
F, FF: Custom Patterns
Q,A Q,A
Q,A - 302H
E1-04
Max Output Frequency
(Fmax)
40.0 to
400.0
0.1 Hz 50.0 Q,A Q,A Q,A Q,A 303H
E1-05 Max Voltage (Vmax)
0.0 to
255.0
<7>
0.1
VAC
200.0
<7>
Q,A Q,A Q,A Q,A 304H
E1-06 Base Frequency (Fa)
0.0 to
400.0
0.1 Hz 50.0 Q,A Q,A Q,A Q,A 305H
E1-07 Mid Output Frequency (Fb)
0.0 to
400.0
0.1 Hz <4> A A A A 306H
E1-08
Mid Output Frequency
Voltage (Vc)
0.0 to
255.0
<7>
0.1
VAC
<4> A A A A 307H
E1-09
Minimum Output Frequency
(Fmin)
0.0 to
400.0
0.1 Hz <4> Q,A Q,A Q,A Q,A 308H
E1-10
Minimum Output Frequency
Voltage (Vmin)
0.0 to
255.0
<7>
0.1
VAC
<4>
A A A A 309H
E1-11 Mid Output Frequency 2
0.0 to
400.0
0.1 Hz 0.0 A A A A 30AH
E1-12
Mid Output Frequency
Voltage 2
0.0 to
255.0
<7>
0.1
VAC
0.0
If these parameters are set to 0.0 they are
ignored in the V/f pattern.
A A A A 30BH
V/f Characteristics
E1-13 Base Voltage (Vbase)
0.0 to
255.0
<7>
0.1
VAC
0.0
If set to 0.0 the base voltage will be the
maximum voltage (E1-05)
Q,A Q,A Q,A Q,A 30CH
E2-01 Motor Rated Current <6> <6> <6> Motor nameplate full load current. Q,A Q,A Q,A Q,A 30EH
E2-02 Motor Rated Slip
0.00 to
20.00
0.01
Hz
<6> Motor rated slip A A A A 30FH
E2-03 Motor No-Load Current <6> <6> <6> Motor no-load current. Set during Auto-Tuning A A A A 310H
E2-04 Number of Motor Poles 2 to 48 2 pole
4 Set the number of motor poles A A A A 311H
E2-05
Motor Line to Line
Resistance
0.000
to
65.000
0.001
<6>
Motor line to line resistance. Set during
Auto-Tuning
A A A A 312H
E2-06 Motor Leakage Inductance
0.0 to
40.0
0.1%
<6>
Motor leakage inductance. Set during
Auto-Tuning
A A A A 313H
E2-07
Motor Iron Core Saturation
Co-Efficient 1
0.00 to
0.50
- 0.50
Motor iron saturation coefficient at 50% of
magnetic flux. Set during Auto-tuning
- - A A 314H
E2-08
Motor Iron Core Saturation
Co-Efficient 2
0.00 to
0.75
- 0.75
Motor iron saturation coefficient at 75% of
magnetic flux. Set during Auto-tuning
- - A A 315H
E2-09 Motor Mechanical Loss
0.0 to
10.0
0.1% 0.0
Motor mechanical loss as a % of motor rated
power
- - A A 316H
E2-10
Motor Iron Loss for Torque
Compensation
0 to
65535
1 W <6> Motor Iron Loss A A - - 317H
Motor Parameters
E2-11 Motor Rated Power
0.00 to
650.00
0.01
kW
<6> Motor nameplate rated power Q,A Q,A Q,A Q,A 318H
<1> Access Levels A: Advanced Programming Menu Q: Quick Setting Menu -: N/A in this Control Mode
<4> Default Setting is determined by the control method (A1-02 or E3-01)
<6> Default Setting and/or Setting Range is determined by drive capacity rating
<7> Values shown are for 200 VAC class drives. For 400 VAC class drives these values are doubled.