Specifications
YASKAWA Inverter Drive A1000 – Crane Software Application Manual
22
Access Level <1>
No. Parameter Name
Setting
Range
Units Default Description
During
Run
V/f
V/f
with PG
OLV CLV
MEMOBUS
Address
o3-01 Copy Function Selection 0 to 3 0
0: No action
1: Read parameters from the drive, saving
them onto the digital operator
2: Copy parameters from the digital operator,
writing them to the drive
3: Verify parameter settings on the drive to
check if they match the data saved on the
operator
A A A A 515H
Copy Function
o3-02 Copy Allowed Selection 0,1 0
0: Read operation prohibited
1: Read operation allowed
A A A A 516H
o4-01
Cumulative Operation Time
Setting
0 to
9999
10 h 0 Cumulative operation time of the drive A A A A 50BH
o4-02
Cumulative Operation Time
Selection
0,1 0
0: Logs power-on time
1: Logs operation time when the drive output
is active (output operation time).
A A A A 50CH
o4-03
Cooling Fan Operation Time
Setting
0 to
9999
10 h 0 Value of fan operation time (U4-03) A A A A 50EH
o4-05 Capacitor Maintenance Setting
0 to
150
1% 0 Value of maintenance monitor for capacitors A A A A 51DH
o4-07
DC Bus Soft-charge Relay
Maintenance Setting
0 to
150
1% 0
Value of maintenance monitor for the
soft-charge bypass relay
A A A A 523H
o4-09 IGBT Maintenance Setting
0 to
150
1% 0 Value of maintenance monitor for the IGBTs A A A A 525H
o4-11 U2,U3 Monitor Initialization 0,1 0
0: U2-
and U3-
monitor data is not reset when
the drive is initialized
1: U2-
and U3-
monitor data is reset when the
drive is initialized
A A A A 510H
o4-12 kWh Monitor Initialization 0,1 0
0: U4-10 and U4-11 monitor data is not reset
when the drive is initialized
1: U4-10 and U4-11 monitor data is reset
when the drive is initialized
A A A A 512H
Maintenance
o4-13
Number of Run Commands
Counter Initialization
0,1 0
0: Number of Run commands counter is not
reset when the drive is initialized
1: Number of Run commands counter is reset
when the drive is initialized
A A A A 528H
<1> Access Levels A: Advanced Programming Menu Q: Quick Setting Menu -: N/A in this Control Mode