Specifications
YASKAWA Inverter Drive A1000 – Crane Software Application Manual 
31 
Parameter Defaults that Change According to Control Mode 
Default Setting 
No.  Name  Setting Range 
Setting 
Units 
V/f 
A1-02=0 
V/f with PG 
A1-02=1 
OLV 
A1-02=2 
CLV 
A1-02=3 
b2-01  Zero Speed Level    0.0 to 10.0  0.1 Hz  0.5  0.5  0.5  0.50 
b2-04  DC Injection Braking Time at Stop  0.00 to 10.00  0.01 s  0.00  0.00  0.00  0.50 
C2-01  S-Curve Characteristic at Accel Star  0.00 to 10.00  0.01 s  0.20  0.20  0.20  0.20 
C3-01  Slip Compensation Gain    0.0 to 2.5  -  0.0  ― 1.0 1.0 
C3-02 
Slip Compensation Primary Delay 
Time 
0 to 10000  1 ms  2000  ― 200 ― 
C4-01  Torque Compensation Gain    0.00 to 2.50  -  1.00  1.00  1.00  ― 
C4-02 
Torque Compensation Primary Delay 
Time 
0 to 10000  1 ms  200  200  20  ― 
C5-01  ASR Proportional Gain 1 (P)  0.00 to 300.00  -  ― 0.20 ― 20.00 
C5-02  ASR Integral Time 1 (I)  0.000 to 10.000  0.001 s  ― 0.200 ― 0.500 
C5-03  ASR Proportional Gain 2 (P)  0.00 to 300.00  0.01  ― 0.02 ― 20.00 
C5-04  ASR Integral (I) Time 2  0.000 to 10.000  0.001 s  ― 0.050 ― 0.500 
C5-06  ASR Primary Delay Time Constant    0.000 to 0.500    ―  ―  ― 0.004 
E1-07 
E3-05 
Mid Output Frequency (Fb)  0.0 to 400.0  0.1 Hz  2.5  2.5  3.0  ― 
E1-08 
E3-06 
Mid Output Frequency Voltage (Vc) 
0.0 to 255.0 
<7> 
0.1 VAC  <18>  <18>  <18>  ― 
E1-09 
E3-07 
Minimum Output Frequency (Fmin)  0.0 to 400.0  0.1 Hz  1.3  1.3  0.5  0.0 
E1-10 
E3-08 
Minimum Output Frequency Voltage 
(Vmin) 
0.0 to 255.0 
<7> 
0.1 VAC  <18>  <18>  <18>  ― 
F1-01  PG 1 Pulses  0 to 60000  1 ppr  ― 1024 ― 1024 
F1-05  PG 1 Rotational Selection    0 to 1  ―  ― 0  ― 0 
F1-09  Overspeed (os) Detection Delay Time    0.0 to 2.0  0.1 s  ― 1.0 ― 0.0 
L3-20  Main Circuit Voltage Tuning Gain    0.00 to 5.00  0.01  1.00  1.00  0.30  0.30 
L8-38  Carrier Frequency Reduction    0 to 2  ―  <18>  <18>  <18>  <18> 
o1-04  V/f Display Units  0 to 1  ―  ―  ―  ― 0 
S1-03  Brake Delay Frequency    0.0 to 400.0  0.1 Hz  3.0  3.0  3.0  0.0 
S1-04  Brake Delay Time    0.00 to 10.00  0.01 s  0.30  0.30  0.30  0.00 
S1-09  Torque Compensation (FWD)  <8> 1% ―  ― 50 0 
S1-14  Slip Prevention Frequency    0.0 to 20.0  0.1 Hz  3.0  3.0  3.0  0.0 
S1-15  Slip Prevention Time    0.00 to 10.00  0.01 s  0.30  0.30  0.30  0.00 
S3-01  Impact Stop Creep Frequency    0.0 to 20.0  0.1 Hz  6.0  6.0  3.0  3.0 
<7>  Values shown are for 200 VAC class drives. For 400 VAC class drives these values are doubled. 
<8>  Setting Range is determined by the control method (A1-02) 
<18> Default Setting is not just determined by control mode but also by drive capacity 