Specifications
YASKAWA Inverter Drive A1000 – Crane Software Application Manual
33
400 V Class
No. Parameter Name Units Default Setting
-
Drive Capacity
E2-11 Motor Rated Output
E4-07 Motor 2 Rated Output
kW 0.4 0.75 1.5 2.2 3.0 3.7 5.5 7.5 11 15
o2-04 Drive kVA Selection - 92 93 94 95 96 97 99 9A 9C 9D
C5-17 Motor Inertia kgm
2
0.0015 0.0028 0.0068 0.0088 0.0158 0.0158 0.026 0.037 0.053 0.076
E2-01
(E4-01)
Motor Rated Current A 1.00 1.60 3.10 4.20 5.70 7.00 9.80 13.30 19.9 26.5
E2-02
(E4-02)
Motor Rated Slip Hz 2.90 2.60 2.50 3.00 2.70 2.70 1.50 1.30 1.70 1.60
E2-03
(E4-03)
Motor No-Load Current A 0.60 0.80 1.40 1.50 1.90 2.30 2.60 4.00 5.6 7.6
E2-05
(E4-05)
Motor Resistance Between Lines Ω 38.198 22.459 10.100 6.495 4.360 3.333 1.595 1.152 0.922 0.550
E2-06
(E4-06)
Motor Leakage Inductance % 18.2 14.3 18.3 18.7 19.0 19.3 18.2 15.5 19.6 17.2
E2-10 Motor Iron Loss for Torque Compensation W 14 26 53 77 105 130 193 263 385 440
L3-24 Inertia Calculated Acceleration Time s 0.178 0.142 0.166 0.145 0.145 0.154 0.168 0.175 0.265 0.244
L8-02 Overheat Pre-Alarm Operation Selection ― 110 110 110 110 110 110 110 115 120 120
L8-35 Installation Method Selection ― 2 2 2 2 2 2 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10 10 10
n5-02 Motor Acceleration Time s 0.178 0.142 0.166 0.145 0.145 0.154 0.168 0.175 0.265 0.244
400 V Class
No. Parameter Name Units Default Setting
-
Drive Capacity
E2-11 Motor Rated Output
E4-07 Motor 2 Rated Output
kW 18.5 22 30 37 45 55 75 90 110 132
o2-04 Drive kVA Selection - 9E 9F A1 A2 A3 A4 A5 A6 A7 A8
C5-17 Motor Inertia kgm
2
0.138 0.165 0.220 0.273 0.333 0.490 0.900 1.10 1.90 2.10
E2-01
(E4-01)
Motor Rated Current A 32.9 38.6 52.3 65.6 79.7 95.0 130.0 156.0 190.0 223.0
E2-02
(E4-02)
Motor Rated Slip Hz 1.67 1.70 1.80 1.33 1.60 1.46 1.39 1.40 1.40 1.38
E2-03
(E4-03)
Motor No-Load Current A 7.8 9.2 10.9 19.1 22.0 24.0 36.0 40.0 49.0 58.0
E2-05
(E4-05)
Motor Resistance Between Lines Ω 0.403 0.316 0.269 0.155 0.122 0.088 0.092 0.056 0.046 0.035
E2-06
(E4-06)
Motor Leakage Inductance % 20.1 23.5 20.7 18.8 19.9 20.0 20.0 20.0 20.0 20.0
E2-10 Motor Iron Loss for Torque Compensation W 508 586 750 925 1125 1260 1600 1760 2150 2350
L3-24 Inertia Calculated Acceleration Time s 0.317 0.355 0.323 0.320 0.387 0.317 0.533 0.529 0.646 0.673
L8-02 Overheat Pre-Alarm Operation Selection ― 115 120 120 110 120 130 130 120 110 120
L8-35 Installation Method Selection ― 2 0 0 0 0 0 0 0 0 0
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 30 30 30 30 30
n5-02 Motor Acceleration Time s 0.317 0.355 0.323 0.320 0.387 0.317 0.533 0.592 0.646 0.673
400 V Class
No. Parameter Name Units Default Setting
-
Drive Capacity
E2-11 Motor Rated Output
E4-07 Motor 2 Rated Output
kW 160 185 220 300
o2-04 Drive kVA Selection - A9 AA AC AE
C5-17 Motor Inertia kgm
2
3.30 3.60 4.10 11.0
E2-01
(E4-01)
Motor Rated Current A 270.0 310.0 370.0 500.0
E2-02
(E4-02)
Motor Rated Slip Hz 1.35 1.30 1.30 1.25
E2-03
(E4-03)
Motor No-Load Current A 70.0 81.0 96.0 130.0
E2-05
(E4-05)
Motor Resistance Between Lines Ω 0.029 0.025 0.020 0.014
E2-06
(E4-06)
Motor Leakage Inductance % 20.0 20.0 20.0 20.0
E2-10 Motor Iron Loss for Torque Compensation W 2850 3200 3700 4700
L3-24 Inertia Calculated Acceleration Time s 0.777 0.864 0.910 1.392
L8-02 Overheat Pre-Alarm Operation Selection ― 130 140 140 140
L8-35 Installation Method Selection ― 0 0 0 0
n1-03 Hunting Prevention Time Constant ms 30 100 100 100
n5-02 Motor Acceleration Time s 0.777 0.864 0.910 1.392