S2-03 Run Command Delay Timer: When a hoist command is entered immediately after the load has been lowered in V/f 
and Open Loop Vector control modes, a large amount of current may flow through the drive and trigger a fault. To reduce 
the output current peak the hoist command can be delayed using this parameter. To calculate an appropriate time for this 
parameter use the following formula: 
()()
()()
s
EE
EE
S 5.1
0320222
032012
032
22
⋅
−⋅−⋅
−−−
=−
π
No.  Parameter Name  Setting Range  Default 
S2-03 
Run Command Delay Timer  0.00 to 10.00 s  0.00 s 
7.2.2 Run Command Adjustment Operation
The following time chart shows drive operation when Run Command Minimum On Time parameters are used. 
(1)  When the drive is stopped and a run command is entered (in all control modes): 
•  If the duration of the external run command is shorter than the Minimum On Time (S2-01, -02) then the drive will 
run until the Minimum On Time has expired. 
•  If the duration of the external run command is longer than the Minimum On Time (S2-01, -02), then the drive will 
run until the external run command is removed. 
(2)  When the drive is decelerating and a run command is entered: 
•  When the drive is motoring in the same direction as the run command that has been entered, the drive will 
operate according to the table below. 
Minimum ON Time (S1-01, -02) = 0  Minimum ON Time (S1-01, -02) ≠ 0 
Control Mode 
Output Frequency > F
α
 Output Frequency ≤ F
α
  Output Frequency > F
α
 Output Frequency ≤ F
α
ALL 
Drive Re-accelerates  Brief Stop  Stops for a minimum of 50ms 
•  When the drive is motoring in the opposite direction as the run command that has been entered, the drive will 
operate according to the following table: 
Minimum ON Time (S1-01, -02) = 0  Minimum ON Time (S1-01, -02) ≠ 0 
Control Mode 
Output Frequency > F
α
 Output Frequency ≤ F
α
  Output Frequency > F
α
 Output Frequency ≤ F
α
CLV 
Brake is not applied, 
FWD/REV switching is 
activated 
V/f, V/f with PG, OLV 
Stops for a minimum of 50 ms 
Time
OutputFrequency
RunCmdProhibited
InternalRunCmd
FWD(REV)RunCmd
S2‐01(‐02)
S2‐01(‐02)
50ms 50ms