Specifications
YASKAWA Inverter Drive A1000 – Crane Software Application Manual
62
No. Parameter Name Default
Setting
Value
No. Parameter Name Default
Setting
Value
F4-02 Terminal V1 Monitor Gain 100.0 H2-02 Terminal P1-PC Function Selection (photocoupler) 0
F4-03 Terminal V2 Monitor Selection 103 H2-03 Terminal P2 Function Selection (photocoupler) 2
F4-04 Terminal V2 Monitor Gain 50.0 H2-06 Estimated Power Pulse Output Unit Selection 0
F4-05 Terminal V1 Monitor Bias 0.0 H3-01 Terminal A1 Signal Level Selection 0
F4-06 Terminal V2 Monitor Bias 0.0 H3-02 Terminal A1 Function Selection 0
F4-07 Terminal V1 Signal Level 0 H3-03 Terminal A1 Input Gain 100.0
F4-08 Terminal V2 Signal Level 0 H3-04 Terminal A1 Input Bias 0.0
F5-01 Terminal M1-M2 Output Selection 0 H3-05 Terminal A3 Signal Level Selection 0
F5-02 Terminal M3-M4 Output Selection 1 H3-06 Terminal A3 Function Selection 2
F5-03 Terminal P1-PC Output Selection 2 H3-07 Terminal A3 Input Gain 100.0
F5-04 Terminal P2-PC Output Selection 4 H3-08 Terminal A3 Input Bias 0.0
F5-05 Terminal P3-PC Output Selection 6 H3-09 Terminal A2 Signal Level Selection 2
F5-06 Terminal P4-PC Output Selection 37 H3-10 Terminal A2 Function Selection 0
F5-07 Terminal P5-PC Output Selection F H3-11 Terminal A2 Input Gain 100.0
F5-08 Terminal P6-PC Output Selection F H3-12 Terminal A2 Input Bias 0.0
F5-09 DO-A3 Output Mode Selection 0 H3-13 Analog Input Filter Time Constant 0.03
F6-01 Communications Error Operation Selection 1 H3-14 Analog Input Terminal Enable Selection 7
F6-02
Selection of External Fault from Communication
Option Board
0 H3-16 Terminal A1 Tuning Offset 0
F6-03
Stopping Method for External Fault from
Communication Option Board
1 H3-17 Terminal A2 Tuning Offset 0
F6-04
Trace Sampling from Communications Option
Board
H3-18 Terminal A3 Tuning Offset 0
F6-06
Torque Reference/Torque Limit Selection from
Communications Option
H4-01 Terminal FM Monitor Selection 102
F6-07 NetRef/ComRef Selection 2.0 H4-02 Terminal FM Output Gain 100.0
F6-08 Reset Communication Parameters 0 H4-03 Terminal FM Bias 0.0
H1-01 Terminal S1 Function Selection 0 H4-04 Terminal AM Monitor 103
H1-02 Terminal S2 Function Selection 0 H4-05 Terminal AM Gain 50.0
H1-03 Terminal S3 Function Selection 40 H4-06 Terminal AM Bias 0.0
H1-04 Terminal S4 Function Selection 41 H4-07 Terminal FM Signal Level Selection 0
H1-05 Terminal S5 Function Selection 24 H4-08 Terminal AM Signal Level Selection 0
H1-06 Terminal S6 Function Selection 14 H5-01 Node Address 1f
H1-07 Terminal S7 Function Selection 0 H5-02 Communication Speed Selection 3
H1-08 Terminal S8 Function Selection 9 H5-03 Communication Parity Selection 0
H2-01 Terminal M1-M2 Function Selection (Relay) 21 H5-04 Stopping Method After Communication Error (CE) 3