Specifications

YASKAWA Inverter Drive A1000 – Crane Software Application Manual
63
No. Parameter Name Default
Setting
Value
No. Parameter Name Default
Setting
Value
H5-05 Conmm. Faulte Detection Selection 1 L3-20 DC Bus Voltage Tuning Gain 0.30
H5-06 Drive Transmit Wait Time 5 L3-21 Accel/Decel Rate Calculation Gain 1.00
H5-07 RTS Control Selection 1 L3-23
Automatic Reduction Selection for Stall Prevention
during Run
0
H5-09 Communication Error Detection Time 2.0 L3-24
Motor Acceleration Time for
Inertia Calculations
0.178
H5-10
Unit Selection for MEMOBUS/Modbus Register
0025H
0 L3-25 Load Inertia Ratio 1.0
H5-11 Communications ENTER Function Selection 0 L3-26 Additional DC Bus Capacitors 0
H5-12 Run Command Method Selection 0 L3-27 Stall Prevention Detection Time 50
H6-01 Pulse Train Input Function Selection 0 L4-01 Frequency Detection Level 0.0
H6-02 Pulse Train Input Scaling 1440 L4-02 Frequency Detection Width 2.0
H6-03 Pulse Train Input Gain 100.0 L4-03
Frequency Detection Level (+/
)
0.0
H6-04 Pulse Train Input Bias 0.0 L4-04
Frequency Detection Width (+/
)
2.0
H6-05 Pulse Train Input Filter Time 0.10 L4-05 Frequency Reference Loss Detection Selection 0
H6-06 Pulse Train Monitor Selection 102 L4-06 Frequency Reference at Reference Loss 80.0
H6-07 Pulse Train Monitor Scaling 1440 L4-07 Speed Agreement Detection Selection 0
H6-08 Pulse Train Input Minimum Frequency 0.5 L7-01 Forward Torque Limit 200
L1-01 Motor Protection Function Selection 1 L7-02 Reverse Torque Limit 200
L1-02 Motor Protection Operation Time 1.0 L7-03 Forward Regenerative Torque Limit 200
L1-03
Motor Overheat Alarm Operation Selection (PTC
input)
3 L7-04 Reverse Regenerative Torque Limit 200
L1-04 Motor Overheat Operation Selection 1 L7-06 Torque Limit Integral Time Constant 200
L1-05 Motor Temperature Input Filter Time Constant 0.20 L7-07
Torque Limit Control Method Selection during
Accel/Decel
0
L1-13 Continuous Electrothermal Operation Selection 1 L8-01
Internal Dynamic Braking Resistor Protection
Selection (ERF type)
0
L2-05 DC Bus Undervoltage Detection Level 190 L8-02 Overheat Alarm Level 115
L3-01 Stall Prevention Selection during Acceleration 1 L8-03 Overheat Pre-Alarm Operation Selection 3
L3-02 Stall Prevention Level during Acceleration 150 L8-05 Input Phase Protection Selection 1
L3-03 Stall Prevention Limit during Acceleration 50 L8-07 Output Phase Protection Selection 1
L3-04 Stall Prevention Selection during Deceleration 0 L8-08 Output Phase Detection Level 5.0
L3-05 Stall Prevention Selection during Run 1 L8-09 Ground Protection Selection 1
L3-06 Stall Prevention Level during Run 160 L8-10 Heatsink Cooling Fan Operation Selection 0
L3-11 Overvoltage Suppression Function Selection 0 L8-11 Heatsink Cooling Fan Off Delay Time 60
L3-17
Target DC Bus Voltage for Overvoltage
Suppression and Stall Prevention
375v L8-12 Ambient Temperature Setting 40