Specifications
YASKAWA Inverter Drive A1000 – Crane Software Application Manual
65
No. Parameter Name Default
Setting
Value
No. Parameter Name Default
Setting
Value
S1-15 Slip Prevention Time 0.30 S4-16 Swift Lift 2 Fault Detection Time 0.1
S1-16 Sequence Fault SE1 Detection Time 0.30 S4-17 Swift Lift 2 Accel Time Gain 2.0
S1-17 Sequence Fault SE2 Detection Time 1.00 S4-18 Swift Lift 2 Operation Selection during Regeneration 0
S1-18 Sequence Fault SE3 Detection Time 0.50 S4-19 Swift Lift 1 Torque Bias (FWD) 0.0
S1-19 Sequence Fault SE4 Detection Time 0.50 S4-20 Swift Lift 1 Torque Bias (REV) 0.0
S1-20 Operation in Reverse 0 S5-01 Overload Detection Operation Selection 1 0
S2-01
Run Command Minimum On Time (FWD)
0.00
S5-02 Overload Detection Torque 1 150
S2-02
Run Command Minimum On Time (REV)
0.00
S5-03 Overload Detection Time 1 0.1
S2-03
Run Command Delay Timer ( Reverse Forward )
0.00
S5-04 Overload Detection Operation Selection 2 0
S3-01 Impact Stop Creep Frequency 3.0 S5-05 Overload Detection Torque 2 150
S3-02 Impact Stop Creep Frequency 10.0 S5-06 Overload Detection Time 2 0.1
S3-03 Impact Stop Detection Torque (FWD) 100 S6-01 Overtorque Detection Operation Selection 1 0
S3-04 Impact Stop Detection Torque (REV) 100 S6-02 Overtorque Detection Level 1 150
S3-05 Impact Stop Detection Time 0.3 S6-03 Overtorque Detection Time 1 0.1
S4-01 Swift Lift Control Selection 0 S6-04 Overtorque Detection Operation Selection 2 0
S4-02 Swift Lift 1 Max. Frequency (FWD) 60.0 S6-05 Overtorque Detection Level 2 150
S4-03 Swift Lift 1 Max. Frequency (REV) 60.0 S6-06 Overtorque Detection Time 2 0.1
S4-04 Swift Lift 1 Detection Torque (FWD) 50
S4-05 Swift Lift 1 Detection Torque (REV) 50
S4-06 Swift Lift 1 Detection Frequency 60.0
S4-07 Swift Lift 1 Detection Time 1.0
S4-08 Swift Lift 2 Activation Frequency 50
S4-09 Swift Lift 2 Motoring Limit Start Level 50
S4-10 Swift Lift 2 Motoring Hold Level 100
S4-11 Swift Lift 2 Regen Limit Start Level 10
S4-12 Swift Lift 2 Regen Hold Level 100
S4-13 Swift Lift 2 Limit Timer 1.0
S4-14 Swift Lift 2 Fault Operation Selection 2
S4-15 Swift Lift 2 Fault Detection Level 150