InvErtEr SErIES HIGH PErformAncE vEctor control A1000 En DE ES fr It A1000 A1000 A1000 A1000 A1000
A1000 YASKAWA A1000 HIGH PErformANcE DrIVE contents content Page 2 Experience & Innovation A leader in Inverter Drives technology main features Page 3 customize Your Drive Page 4/5 Permanent magnet motor control Page 6/7 Safety features & communication Page 8/9 Easy start-up and reliable operation Page 10/11 Drive Design & features Experience & Innovation for or more than 90 years YASKAWA has been manufacturing and supplying mechatronic products for machine building and industrial automation.
Permanent magnet motor control Open loop position control (No Motor Feedbacc) Feedbacc) c 200% rated torque at 0 rpm New Auto-Tuning Features Tuning of the Speed Loop according to Load Power Loss Recovery Safety features & communication Safety Torque Off (STO) according to EN954-1 safety category 3, stop category 0; EN ISO 13849-1 PLd; IEC EN 61508 SiL2 External Device Monitor (EDM) to Observe the Safety Status Easy Start-up & reliable operation Application Parameter Presets Screwless Removable Control Ter
Advanced motor control content Advanced Drive Technology Capable of driving different types of motor. A1000 runs not only induction motors, but also synchronous motors lice IPM*1 and SPM*2 motors with high performance open and closed loop vector control. Minimize equipment needed for your business by using the same drive to run induction and synchronous motors.
New Auto-Tuning Features uto-Tuning features optimize drive parameters for operation with induction motors as A well as synchronous motors to achieve the highest performance levels possible. ptimizing not only the drive and motor performance, but also automatically adjusts O settings relative to the connected machinery. ew Auto-Tuning methods. N A1000 continuously analyzes changes in motor characteristics during operation for highly precise speed control.
Safety features & communication Power Loss & recovery Speed Search Easily find the speed of a coasting motor for a smooth restart. Power supply voltage Applications Perfect for fans, blowers and other rotating, fluid-type applications. Motor speed Output frequency 1750 r/min A1000 offers two ways to handle momentary power loss A1000 is capable of handling momentary power loss with sensorless control for induction motors as well as for synchronous motors.
Safety features as a Standard A1000 provides Safe Torque Off (STO) functional safety in compliance with EN954-1 safety category 3 stop category 0, EN ISO 13849-1, PLd, IEC/EN61508 SIL2. An External Device Monitor (EDM) function has also been added to monitor the safety status of the drive. EN954-1 Safety Cat. 3 Compliance Power supply Controller Safety controller Feedback loop Motor All major Serial communication Protocols RS-422/485 (MEMOBUS/Modbus at 115.2 cbps) standard on all models.
Easy start-up and reliable operation Application Parameter Presets A1000 automatically sets parameters needed for major applications. Selecting the appropriate application optimizes the drive for top performance, while saving time for set up.
Parameter copy function All standard models are equipped with a Parameter Copy Function that allows parameter settings to be easily copied from the drive or uploaded for quiccc setup using the operator. A USB Copy Unit is also available as an even faster, more convenient way to baccc up settings and instantly program the drive.
Drive Design & features content Even more compact Yascawa continues to mace applications even smaller by combining the compact designed drive with the light, efficient design of a synchronous motor. Comparing drive dimensions Comparing motor dimensions Example: 400 V Class 75 kW Example shows a 200 V 3.7 kW motor F7 Previous model 55.4% smaller Synchronous motor SMRA Series A1000 Use Side-by-Side installation for an even more compact setup.
Long Performance Life Designed for 10 years of maintenance-free operation. Cooling fan, capacitors, relays, and IGBTs have been carefully selected and designed for a life expectancy up to ten years.* ed for Design rS A E Y 0 1 tenance-free of mainon operati * Assumes the drive is running continuously for 24 hours a day at 80% load with an ambient temperature of 40°C.
Efficiency & Environment content Energy Saving Loaded with advanced energy-saving control technology. Energy-Saving control maces highly efficient operation possible with an induction motor. 13% 80 higher 6.6% Efficiency (%) Amazing energy saving with a synchronous motor Combining the high efficiency of a synchronous motor along with A1000’s Energy-Saving control capabilities allows for unparalleled energy saving.
Standard Specifications Operating Environment Protection Function Control Characteristics Item Specifications Control Method V/f Control, V/f Control with PG, Open Loop Vector Control, Closed Loop Vector Control, Open Loop Vector for PM, Closed Loop Vector for PM, Advanced Open Loop Vector for PM Frequency Control Range 0.01 to 400 Hz Frequency Accuracy (Temperature Fluctuation) Digital reference: within ±0.01% of the max. output frequency (−10 to +40°C) Analog reference: within ±0.1% of the max.
connection Diagram content DC reactor (optional) Terminals -, +1, +2, B1, B2 are for connection options.
terminal functions main circuit terminals Voltage 200 V Model CIMR-AA2A Max. Applicable Motor Capacity*1 kW R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 B1 B2 (−) (+) 1 (+) 2 (+) 3 400 V 2A0004 to 2A0081 2A0110, 2A0138 2A0169, 2A0211 4A0002 to 4A0044 4A0058, 4A0072 4A0088 to 4A0165 0.4 to 18.5 22, 30 37, 45 0.4, 18.
Dimensions content Enclosures Enclosures of standard products vary depending on the model. Refer to the table below. 200 V Class Normal Duty Heavy Duty 0004 0.75 0.4 0006 1.1 0.75 0008 1.5 1.1 0010 2.2 1.5 0018 0021 0030 4.0 5.5 7.5 3 4.0 5.5 Standard Without top and bottom covers Normal Duty Heavy Duty 0002 0.75 0.4 0004 1.5 0.75 0005 2.2 1.5 0007 3 2.2 0009 4.0 3 Model CIMR-AC2A Max. Applicable Motor Capacity [kW] Enclosure Panel [NEMA Type1] Open-Chassis (IP00) 0012 3 2.2 0040 11 7.
Dimensions Enclosure Panel [nEmA type1] Fig. 1 Fig. 2 Fig. 3 200 v class Model CIMR-AC2A Max. applicable motor capacity [kW] Normal Duty 0.75 1.1 2.2 3 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 0004 0006 0010 0012 0021 0030 0040 0056 0069 0081 0110 0138 0169 0211 0250 0312 0360 Heavy Duty 0.4 0.75 1.5 2.2 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 Figure Dimensions in mm W H D W1 H0 H1 H2 H3 D1 t1 t2 d Weight (kg) Cooling 3.1 147 140 260 Fig. 1 38 122 164 248 6 – 55 Fig.
options content Name Input Noise Filter Purpose Reduces noise from the line that enters into the drive input power system. Should be installed as close as possible to the drive. 400V class: Filter of the manufacturer Block are used.
ratings & type Descriptions model number Key CIMR- A C 4 A 0004 F A A AC Drive Inverter Series A1000 Revision A 1st Region code Asia Japan Europe Environmental Specification Standard Humidity, dust Oil Shock, vibration Gas T A C Voltage Class 3-phase, 200-240 VAC 3-phase, 380-480 VAC 2 4 A M N S K Enclosure Type IP00 NEMA Type1 Customized Specification Standard model A A A F Note: Contact Yaskawa for more information on environmental tolerance specifications.
YASKAWA Electric Europe GmbH Hauptstr. 185 65760 Eschborn Deutschland / Germany +49 6196 569-300 info@yaskawa.de www.yaskawa.eu.com A Specifications are subject to change without notice for ongoing product modifications and improvements. © YASKAWA Electric Europe GmbH. All rights reserved. Literature No.