Specifications
18
YASKAWA A1000
Content
Options
Name Purpose Model
Input Noise Filter
Reduces noise from the line that enters into the drive input power system. Should be installed as close as possible to the drive.
400V class: Filter of the manufacturer Block are used. Class C1 and footmounting up to 15 kW (HD), Class C2 and side mounting up to 110 kW (HD)
4A0002
AA
FB-40008A
4A0004
AA
4A0005
AA
4A0007
AA
4A0009
AA
FB-40014A
4A0011
AA
4A0018
AA
FB-40025A
4A0023
AA
4A0031
AA
FB-40044A
4A0038
AA
4A0044
AA
FB-40060A
4A0058
AA
4A0072
AA
FB-40072A
4A0088
AA
FB-40105A
4A0103
AA
4A0139
AA
FB-40170A
4A0165
AA
4A0208
AA
FB-40250A
4A0250
AA
AC Chokes
Reducing Harmonics
B06040 Series
Analog input
Enables high-precision and high-resolution analog speed reference setting.
• Input signal level: -10 to +10 Vdc (20 kΩ) 4 to 20 mA (500 Ω)
• Input channels: 3 channels, DIP switch for input voltage/input current selection
• Input resolution: Input voltage 13 bit signed (1/8192) Input current 1/6554
AI-A3
Digital Input
Enables 16-bit digital speed reference setting.
• Input signal: 16 bit binary, 2 digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
Selectable Parameter: 8 bit, 12 bit, 16 bit
DI-A3
DeviceNet
communications interface
Used for running or stopping the drive, setting or referencing parameters and monitoring output frequency, output current, or similar items through
DeviceNet communication with the host controller
SI-N3
CC-Link
communications interface
Used for running or stopping the drive, setting or referencing parameters and monitoring output frequency, output current, or similar items through
CC-Link communication with the host controller.
SI-C3
CANopen
communications interface
Used for running or stopping the drive, setting or referencing parameters and monitoring output frequency, output current, or similar items through
CANopen communication with the host controller.
SI-S3
MECHATROLINK
communications interface
Used for running or stopping the drive, setting or referencing parameters and monitoring output frequency, output current, or similar items through
MECHATROLINK communication with the host controller.
SI-T3
PROFIBUS-DP
communications interface
Used for running or stopping the drive, setting or referencing parameters and monitoring output frequency, output current, or similar items through
CANopen communication with the host controller.
SI-P3
Analog monitor
Outputs analog signal for monitoring drive output state (output freq., output current etc.)
• Output resolution: 11 bit signed (1/2048)
• Output voltage: −10 to +10 Vdc (non-isolated)
• Output channels: 2 channels
AO-A3
Digital output
Outputs isolated type digital signal for monitoring drive run state (alarm signal, zero speed detection, etc.).
Output channel: Photo coupler 6 channels (48 V, 50 mA or less) Relay contact output 2 channels 250 Vac, 1 A or less 30 Vdc, 1 A or less
DO-A3
Open collector PG
interface
For control modes requiring a PG encoder for motor feedback.
• Phase A, B, and Z pulse inputs (complementary type)
• PG frequency range: Approx. 50 kHz max.
• Pulse monitor output: Open collector, max. voltage: 24 V, max. current 30 mA
• Power supply output for PG: +12 V, max. current 200 mA
PG-B3
Line Driver PG
interface
For control modes requiring a PG encoder for motor feedback.
• Phase A, B, and Z pulse (differential pulse) inputs (RS-422)
• PG frequency range: up to 300 kHz (approx.)
• Pulse monitor output: RS-422
• Power supply output for PG: +5 V or +12 V, max. current 200 mA
PG-X3
LED Operator
Easy long distance reading
JVOP-182
Braking Resistor
Used to shorten the deceleration time by dissipating regenerative energy through a resistor. (3% ED) (all models up to 3,7 kW)
ERF-150WJ series
Braking Chopper Unit
Shortened deceleration time results when used with a Braking Transistor Unit.
CDBR series
24 V Power Supply
Provides power supply for the control circuit and option boards. Note: Parameter settings cannot be changed when the drive is operating solely from
this power supply.
PS-A10H
PS-A10L
USB Copy Unit
(RJ-45/USB compatible plug)
• Adapter for connecting the drive to the USB port of a PC
• Can copy parameter settings easily and quickly to be later transferred to another drive.
JVOP-181
LCD operator extension cable
Cable for connecting the LCD operator.
WV001: 1 m
WV003: 3 m
Note: contact the manufacturer in question for availability and speci
fi