YASKAWA Electric Corporation MP Series SIO (Extension) Driver 1 System Configuration....................................................................................................... 3 2 Selection of External Device ............................................................................................ 6 3 Example of Communication Setting ................................................................................. 7 4 Setup Items ......................................................
MP Series SIO (Extension) Driver Introduction This manual describes how to connect the Display and the External Device (target PLC). In this manual, the connection procedure will be described by following the below sections: 1 System Configuration This section shows the types of External Devices which can be connected and SIO type. )"1 System Configuration" (page 3) 2 Selection of External Device Select a model (series) of the External Device to be connected and connection method.
MP Series SIO (Extension) Driver 1 System Configuration The system configuration in the case when the External Device of YASKAWA Electric Corporation and the Display are connected is shown. Series MP2000 CPU Link I/F MP2300 MP2200 MP2310 MP2300S SIO Type Setting Example Serial port on 218IF-01 RS232C "3.1 Setting Example 1" (page 7) " Cable Diagram 1" (page 14) Serial port on 218IF-02 RS232C "3.1 Setting Example 1" (page 7) " Cable Diagram 1" (page 14) Serial port on 260IF-01 RS232C "3.
MP Series SIO (Extension) Driver COM Port of IPC When connecting IPC with External Device, the COM port which can be used changes with series and SIO type. Please refer to the manual of IPC for details.
MP Series SIO (Extension) Driver Dip switch setting: RS-422/485 (4 wire) Dip switch Setting Description 1 OFF 2 ON 3 ON 4 OFF Output mode of SD (TXD) data: Always output 5 OFF Terminal resistance (220Ω) insertion to SD (TXD): None 6 OFF Terminal resistance (220Ω) insertion to RD (RXD): None 7 OFF Short-circuit of SDA (TXA) and RDA (RXA): Does not Exist 8 OFF Short-circuit of SDB (TXB) and RDB (RXB): Does not Exist 9 OFF 10 OFF Reserve (always OFF) SIO type: RS-422/485 RS (RTS) A
MP Series SIO (Extension) Driver 2 Selection of External Device Select the External Device to be connected to the Display. Setup Items Setup Description Maker Select the maker of the External Device to be connected. Select "YASKAWA Electric Corporation". Driver Select a model (series) of the External Device to be connected and connection method. Select "MP Series SIO (Extension)". Check the External Device which can be connected in "MP Series SIO (Extension)" in system configuration.
MP Series SIO (Extension) Driver 3 Example of Communication Setting Examples of communication settings of the Display and the External Device, recommended by Pro-face, are shown. 3.1 Setting Example 1 Settings of GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
MP Series SIO (Extension) Driver Settings of External Device Communication setting of communication module by ladder software (MPE720). Please refer to the manual of external device for more detail. Ladder Software Setting 1 2 Start ladder software, make an order folder and a PLC folder in a root folder. Click the right button of the PLC which select logon in the displayed menu. • Logon after confirming that a check does not begin [online] of a displayed menu.
MP Series SIO (Extension) Driver 4 Setup Items Set communication settings of the Display with GP-Pro EX or in off-line mode of the Display. The setting of each parameter must be identical to that of External Device. )"3 Example of Communication Setting" (page 7) 4.1 Setup Items in GP-Pro EX Communication Settings To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
MP Series SIO (Extension) Driver Device Setting Setup Items Station No. Setup Description Enter a station number of the External Device, using 1 to 63.
MP Series SIO (Extension) Driver 4.2 Setup Items in Off-Line Mode • Refer to the Maintenance/Troubleshooting manual for information on how to enter off-line mode or about the operation. Cf. Maintenance/Troubleshooting Manual "2.2 Off-line Mode" Communication Settings To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings] in off-line mode. Touch the External Device you want to set from the displayed list.
MP Series SIO (Extension) Driver Setup Items Setup Description Wait To Send (ms) Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving packets to transmitting next commands. Device Setting To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device you want to set from the displayed list, and touch [Device]. Setup Items Setup Description Device/PLC Name Select the External Device for device setting.
MP Series SIO (Extension) Driver Option To display the setting screen, touch [Device/PLC Settings] from [Peripheral Settings]. Touch the External Device you want to set from the displayed list, and touch [Option]. Setup Items RI/VCC Setup Description You can switch RI/VCC of the 9th pin when you select RS232C for SIO type. It is necessary to change RI/5V by changeover switch of IPC when connect with IPC. Please refer to the manual of the IPC for more detail.
MP Series SIO (Extension) Driver 5 Cable Diagram The cable diagram shown below may be different from the cable diagram recommended by Fuji Electric Corporation. Please be assured there is no operational problem in applying the cable diagram shown in this manual. • The FG pin of the External Device body must be D-class grounded. Please refer to the manual of the External Device for more details. • SG and FG are connected inside the Display.
MP Series SIO (Extension) Driver 6 Supported Device Range of supported device address is shown in the table below. Please note that the actually supported range of the devices varies depending on the External Device to be used. Please check the actual range in the manual of your connecting equipment. This address can be specified as system data area.
MP Series SIO (Extension) Driver 7 Device Code and Address Code Use device code and address code when you select "Device Type & Address" for the address type in data displays.
MP Series SIO (Extension) Driver 8 Error Messages Error messages are displayed on the screen of Display as follows: "No. : Device Name: Error Message (Error Occurrence Area)". Each description is shown below. Item Description No. Error No. Device Name Name of External Device where error occurs. Device name is a title of External Device set with GP-Pro EX.((Initial value [PLC1]) Error Message Displays messages related to the error which occurs.
MP Series SIO (Extension) Driver Error Messages Specific to the External Device Message ID Error Message Description RHxx128 "(Node Name):PLC is busy now(Error Code: [Hex])" PLC is "Busy" RHxx129 "(Node Name):Option module is not mounted(Error Code: [Hex])" Option module not mount.