User`s manual
MP Series Ethernet (Extension) Driver
GP-Pro EX Device/PLC Connection Manual
13
4 Setup Items
Set communication settings of the Display with GP-Pro EX or in off-line mode of the Display.
The setting of each parameter must be identical to that of External Device.
)"3 Example of Communication Setting" (page 5)
4.1 Setup Items in GP-Pro EX
Communication Settings
To display the setting screen, select [Device/PLC Settings] from [System setting window] in workspace.
• Set the Display’s IP address in off-line mode.
Cf. Maintenance/Troubleshooting Manual "2.5 Ethernet Settings"
Setup Items Setup Description
Port No.
Enter a port number of the External Device, using 1024 to 65535. Check into [Auto], and a
port number is set automatically.
Timeout
Use an integer from 1 to 127 to enter the time (s) for which Display waits for the response
from External Device.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how
many times the Display retransmits the command.
Wait To Send
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving
packets to transmitting next commands.