Specifications

56
Application Examples
Conveyor and Lifter
(Insures Safe and Optimum Performance)
Varispeed G7
Sequence
FWD/STOP
REV/STOP
2-Step Speed
Reference
Relay Sequence
BR Brake
Brake
BR
Running
R/L1
S/L2
T/L3
Painting Booth
Geared Motor
with Brake
LS4
for
Stop
LS3
for
Decel
LS1 for
Decel
LS1
for Stop
Shock
Absorber
RUN/STOP
Braking
Resistor
Unit
U/T1
V/T2
W/T3
Varispeed G7
R
Power
Supply
Power
Supply
S
T
R/L1
S/L2
T/L3
Mechanical
Brake
MCCB
RUNF
RUNF
40m/min
LS1
Holding
Type
1m/min
Forward
Run
Reverse Run
Forward Run
(Sequencer)
Reverse Run
(Sequencer)
RUNF
RUNR
SA
SA
SA
SA
BX
RUNR
N
RUNR
N
Digital
Operator
U/T1
V/T2
W/T3
B1
B2
Motor
IM
BX
Braking Resistor
Unit
S1
S2
S5
S6
SC
M1
M2
MB
MC
FWD/Stop
REV/Stop
Master/Aux Speed
Multi-step Speed Input
Frequency
Detection
Fault
LS2
LS4
LS1
LS3
s
r
LS2
Holding
Type
LS3
Holding
Type
LS4
Holding
Type
User
,
s Requirements
Operate using
control circuit terminals
Operation method
selection
b1-02=1
Frequency
reference
d1-03=0 to 400Hz
d1-04=0 to 400Hz
Frequency
detection
H2-01=5
L4-01=0 to 400Hz
Braking signal
Set multi-step speed
operation
Function and Parameter Settings
Application Example
Shuttle
Conveyor
Raw Material
Input Conveyor
Steel Pipe
Conveyor
Lifter
User
,
s Requirements
Applicable Varispeed G7 Function
Function and Parameter Settings
Increase precision of positioning
stop.
Control the braking motor using contact
output from terminals M1 and M2.
S-curve accel/decel
C2-01 to 04=0.0 to 2.5 sec.
Frequency reference
d1-01 to 04=0 to 400Hz
External fault H1-01 to -10=20 to 2F
Control method selection
A1-02=0
Torque limit
L7-01 to -04=0 to 300%
*2
b1-02=1, H2-01=5,
L4-01=0 to 400Hz
Operation method selection
Slip prevention
Accel/decel time
switching
Over torque detection
Over torque detection level
Over torque detection time
L6-01, 04=0-4
L6-02, 05=0 to 300%
L6-03, 06=0 to 10.0 sec.
Control method selection
V/f selection
Free V/f setting
A1-02=0
E1-03=F
E1-04 to 10=Setting
H1-01 to -10=7
The function is provided.
(Select V/f mode)
Check the motor generation torque
using the torque detection function.
Use the free V/f setting function to turn
the motor without excess excitation.
Use the multi-step speed function.
Use the accel/decel time setting function.
Select stop procedures.
Increase torque limit value.
Apply S-curve accel/decel.
Select stop procedure according to
degree of emergency.
Increase starting torque
(with a constant-torque motor).
Drive more than one motor with
a single inverter.
Use non-excitation operating type
braking motor.
Perform 2-step speed operation.
Smooth accel/decel
Variable accel/decel time
Simple slip compensation function.
* Inverter capacity cannot be exceeded. Choose larger inverter capacity for the maximum torque required.
Example of Use in Shuttle Conveyor
Conveyor Circuit