To protect
inverter wiring
Objective Name
Model
(Code number)
Details
Ground Fault
Interrupter (GFI)
Magnetic
contactor
Recommended:
NV series
SC series
DCR2
-
=
DGP=
UZDA-=
UZBA-
=
Three-phase
LNFD-
=
FN
=
LF-
=
ERF-150WJ==
LKEB-=
CDBR-=
JVOP-95・=
JVOP-96・=
JGSM-=
P0010 Type (200 V class)
P0020 Type (400 V class)
Surge suppressor
Isolator
DC reactor
AC reactor
Input noise
filter
Output noise
filter
Braking resistor
Braking resistor
unit
Braking unit
VS operator
(Small plastic)
VS operator
(Standard sheet
metal)
VS system
module
Momentary power
loss recovery unit
To prevent burning
(with braking resistor)
To prevent open/
close surge to
the exterior
To isolate input/
output signal
To improve the
inverter input rate
To reduce effect
of noise
interference to
radios and
control devices
To stop the
machine within
the preset time
To protect internal
circuitry in the event
of component failure.
To operate the
inverter by
external control
To operate the
inverter by
system control
To secure inverter
momentary power
loss recovery time
F6045GB
(FIL001098)
F11080GB
(FIL001097)
F200160PB
(300-001-041)
Finemet
zero-phase
reactor to reduce
radio noise
Circuit Breaker
Recommended:
NF series
Always install a circuit breaker on the power-supply
side to protect the power supply system and to prevent
an overload at the occurrence of a short-circuit.
Absorbs the open / close surge of electro-magnetic contactors
and control relays. Always insert the surge suppressor on
magnetic contactors and relays near the inverter.
CR2LS series
CR6L series
CM, CMS series
Fuse / Fuse Holder
Protects internal circuitry in the event of component failure.
Fuse should be connected to the input terminal of the drive.
Note : Refer to the instruction manual for information on UL approval.
Isolates the inverter input / output signal,
and is effective to prevent inductive noise.
Reduces noise circulating to the inverter input
power system, or originating from the wiring.
Insert the filter as near the inverter as possible.
Reduces noise from the line that sneaks into the
inverter input power system. Insert as close to
the inverter as possible.
Can be used on both the input side and output side.
Reduces noise originating from the output side wiring of the
inverter. Insert the filter as near the inverter as possible.
Shortens the deceleration time by consuming the regenerative
energy of the motor by the resistor. (Use rate 3 % ED)
Shortens the deceleration time by consuming the regenerative
energy of the motor by the resistor. (Use rate 10 % ED)
Used in combination with the braking resistor unit
to reduce the deceleration time of the motor.
Control panel that allows remote (50 m max.) frequency
setting and start/stop operation by analog reference.
Frequency meter scale: 60/120 Hz, 90/180 Hz
Control panel that allows remote (50 m max.) frequency
setting and start/stop operation by analog reference.
Frequency meter scale: 75 Hz, 150 Hz, 220 Hz
System controller that allows optimum system integration
by combining with the necessary VS system module
according to the automatic control system.
For momentary power loss of the control power
supply (Power holding time : 2 sec. )
DCF-6A
SCF-12NH
CM-3S
Frequency meter, ammeter
Output voltmeter
Frequency setting knob
Monitor frequencies,
currents, and voltages
Adjust frequency
reference input,
frequency meter,
ammeter scales
Monitors frequencies and currents.
Measures the output voltage externally and
designed for use with PWM inverters.
Adjusts frequency references and the scale on
the meters.
-
(ETX3270)
(ETX3120)
RV30YN20S 2 kΩ
(RH000739)
RV30YN20S 20 kΩ
(RH000850)
Potentiometer for
frequency reference (2kΩ)
Potentiometer for scale
adjustment (20kΩ)
Frequency meter adjusting
potentiometer (20kΩ)
Frequency setting
potentiometer (2kΩ)
Connected to the control circuit terminals to
adjust frequency references and the scales on
the meters.
Applied to improve the input power ratio of the inverter.
The Varispeed G7 incorporates DC reactor on model of
18.5 kW or more (option for model 15 kW or less).
When using large power supply capacity (600 kVA or
more), also install the DC reactor or AC reactor.
When braking resistor is attached, install the contactor to prevent the
braking resistor from burning. Also inset a surge suppressor on the coil.
Always install a GFI on the power-supply side to protect the power supply system
and to prevent an overload at the occurrence of shortcircuit, and to protect the drive
from ground faults that could result in electric shock or fire.
Note: When a GFI is installed for the upper power supply system, an MCCB can be
used instead of a GFI. Choose a GFI designed to minimize harmonics specifically
for AC drives. Use one GFI per drive, each with a current rating of at least 30 mA.