Specifications

Option Cards
68
Type
Built-in type (connected to connector)
Speed (frequency) reference card
Monitor option card
Name
TOE-
C736-30.21
TOBP
C73060026
TOE-
C736-30.24
TOE-
C736-40.8
AO-08
AO-12
DO-08
DO-02C
Analog monitor card
AO-08
Analog monitor card
AO-12
Digital output card
DO-08
2C-relay output card
DO-02C
Model Function
Manual No.
DI-08
TOBP
C73060030
Allows 8-bit digital speed reference setting.
Input signal:
Binary 8 bits/BCD 4 digits + SIGN signal + SET signal
Input voltage:
+24 V (isolated
) Input current: 8 mA
Outputs analog signal for monitoring inverter output state (output freq.,
output current etc.) after absolute value conversion.
Output resolution: 8 bits (1/256)
Output voltage: 0 to +10 V (non isolated) Output channel: 2 channels
TOE-
C736-30.13
AI-14U
Analog reference card
AI-14U
Allows high precision, high resolution analog speed reference setting.
Input signal level:
0 to +10 VDC (20 kΩ) 1 channel
4 to 20 mADC (250
Ω
) 1 channel
Input resolution: 14 bits (1/16384)
TOBP
C73060015
AI-14B
Analog reference card
AI-14B
Digital reference card
DI-08
Allows bipolar high precision, high resolution analog speed reference setting.
Input signal level:
0 to ±10 VDC (20 kΩ)
4 to 20 mADC (500
Ω
) 3 channels
Input resolution: 13 bits + code (1/8192)
TOBP
C73060031
DI-16H2
Digital reference card
DI-16H2
Allows 16-bit digital speed reference setting.
Input signal: Binary 16 bits/BCD 2 digits + SIGN signal + SET signal
Input voltage:
+24 V (isolated
) Input current: 8 mA
With 16-bit/12-bit select function
Outputs analog signal for monitoring inverter output state (output freq.,
output current etc.)
Output resolution: 11 bits (1/2048) + code
Output voltage: −10 to +10 V (non isolated) Output channel: 2 channels
Outputs isolated type digital signal for monitoring inverter run state
(alarm signal, zero speed detection etc.) .
Output channel: Photo coupler 6 channels (48 V, 50 mA or less)
Relay contact output 2 channels
250 VAC, 1 A or less
30 VDC, 1 A or less
Two multi-function contact outputs (2C-relay) can be used other than
those of the inverter proper unit.
SI-C
CC-Link
communications I/F card
SI-C
TOBZ-
C736-70.6
SIBP
C73060008
TOBP
C73060008
SIBP
C73060007
Used for running or stopping the inverter, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through CC-Link communication with the host controller.
SI-J
LONWORKS
communications I/F card
 SI-J
*1
Used for HVAC control, running or stopping the inverter,setting or
referencing parameters, and monitoring output current,watt-hours, or
similar items through LONWORKS communications with the host controller.
TOE-
C736-40.1
TOBP
C73060009
PG-A2
PG-B2
PG-A2
PG-B2
Used for vector control with PG or V/f control with PG
Phase A and B pulse inputs (exclusively for complementary input)
PG frequency range: Approx. 30 kHz max.
[ Power supply output for PG: +12 V, Max. current 200 mA]
Pulse monitor output: Open collector, +24 V, Max. current 30 mA
Pulse generator on motor performs speed feedback to correct speed
fluctuations caused by slipping (for V/f control with PG).
Phase A pulse (single pulse) inputs (voltage, complementary, open
collector input)
PG frequency range: Approx. 30 kHz max.
[ Power supply output for PG: +12 V, max. current 200 mA ]
Pulse monitor output: +12 V, 20 mA
PG speed controller card
*2
Communications option card
SI-T
MECHATROLINK-
communications I/F card
SI-T
Used for running or stopping the inverter, setting or referencing parameters,
and monitoring output frequency, output current, or similar items through
MECHATROLINK-
communication with the host controller.
DeviceNet
communications I/F card
  SI-N1
*1
SI-N1
Used for running or stopping the inverter, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through DeviceNet communication with the host controller.
SIBP
C73060001
SI-P1
Profibus-DP
communications I/F card
  SI-P1
*1
Used for running or stopping the inverter, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through Profibus-DP communication with the host controller.
SIBZ-
C736-70.9
TOBP
C73060011
CANopen
communications I/F card
SI-S1
SI-S1
Used for running or stopping the inverter, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through CANopen communication with the host controller.
RoHS Compliant
RoHS Compliant
RoHS Compliant
RoHS Compliant
RoHS Compliant