Specifications
85
AC Reactor (UZBA-B for Input 50/60 Hz)
When power capacity is significantly greater when compared
to inverter capacity, or when the power-factor needs to be
improved, connect the AC or DC reactor.
Select an AC reactor according to the motor capacity.
Standard Varispeed G7 is a DC reactor.
Max. Applicable
Motor Output
kW
Approx.
Mass
kg
Current
Value
A
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
20
30
40
60
80
90
120
160
200
240
280
360
500
500
Inductance
mH
0.53
0.35
0.265
0.18
0.13
0.12
0.09
0.07
0.05
0.044
0.038
0.026
0.02
0.02
Code No.
Drawing
1
2
Dimensions in mm
X 002491
X 002492
X 002493
X 002495
X 002497
X 002498
X 002555
X 002556
X 002557
X 002558
X 002559
X 002560
X 010145
X 010145
3
3
4
6
8
8
8
12
15
23
23
32
55
55
Loss
W
35
45
50
65
75
90
90
100
110
125
130
145
200
200
A
130
130
130
160
180
180
180
210
210
240
240
270
330
330
B
88
88
98
105
100
100
100
100
115
126
126
162
162
162
B1
114
119
139
147.5
155
150
155
170
182.8
218
218
241
286
286
C
105
105
105
130
150
150
150
175
175
215±5
215±5
230±5
315±5
315±5
D
50
50
50
75
75
75
75
75
75
150
150
150
150
150
E
65
70
75
85
80
80
80
80
95
110
110
130
130
130
F
130
130
130
160
180
180
180
205
205
240
240
260
320
320
H
22
22
22
25
25
25
25
25
25
25
25
40
40
40
J
M 6
M 6
M 6
M 6
M 6
M 6
M 6
M 6
M 6
M 6
M 8
M 8
M 10
M 10
K
11.5
9
11.5
10
10
10
10
10
10
8
8
16
16
16
L
7
7
7
7
7
7
7
7
7
7
10
10
10
10
M
M 5
M 5
M 6
M 6
M 8
M 8
M 10
M 10
M 10
M 10
M 12
M 12
M 12
M 12
200 V Class
7.5
11
15
18.5
22
30
37
45
55
75
90/110
132/160
185
220
300
20
30
40
50
60
80
90
120
150
200
250
330
490
660
1.06
0.7
0.53
0.42
0.36
0.26
0.24
0.18
0.15
0.11
0.09
0.06
0.04
0.03
1
2
3
X 002502
X 002503
X 002504
X 002505
X 002506
X 002508
X 002509
X 002566
X 002567
X 002568
X 002569
X 002570
X 002690
300-032-353
5
6
8
8
8.5
12
15
23
23
32
32
55
60
80
50
65
90
90
90
95
110
130
150
135
135
200
340
310
A
160
160
180
180
180
210
210
240
240
270
270
320
330
330
B
90
105
100
100
100
100
115
126
126
162
162
165
176
216
B1
115
132.5
140
145
150
150
177.5
193
198
231
231
253
293
353
C
130
130
150
150
150
175
175
205±5
205±5
230±5
230±5
230±5
315±5
285±5
D
75
75
75
75
75
75
75
150
150
150
150
150
150
150
E
70
85
80
80
80
80
95
110
110
130
130
130
150
185
F
160
160
180
180
180
205
205
240
240
260
260
320
320
320
H
25
25
25
25
25
25
25
25
25
40
40
40
40
40
J
M 6
M 6
M 6
M 6
M 6
M 6
M 6
M 8
M 8
M 8
M 8
M 10
M 10
M 10
K
10
10
10
10
10
10
10
8
8
16
16
17.5
13
15.5
L
7
7
7
7
7
7
7
10
10
10
10
12
12
18
M
M 5
M 5
M 6
M 6
M 6
M 8
M 8
M 10
M 10
M 10
M 12
M 12
M 12
M 16
400 V Class
Max. Applicable
Motor Output
kW
Approx.
Mass
kg
Current
Value
A
Inductance
mH
Code No.
Drawing
Dimensions in mm
Loss
W
Drawing 1 Drawing 2 Drawing 3
C
4.5
UV W
U
VW
XYZ
XYZ
D
F
A
L
K
H
E
B
B1
D
F
A
C
4.5
H
E
B
B1
U
VW
XYZ
C
4.5
D
F
A
H
E
B
B1
6-M: Terminal
6-M: Terminal
6-M: Terminal
4-J: MTG Holes
4-J: MTG Holes
4-J: MTG Holes
Detail of
MTG Hole
Name Plate
Name Plate
Name Plate
2-M8 Eyebolts
2-M8 Eyebolts
When using low noise type
inverters (high-carrier
frequency of 2.5 kHz or
more), do not connect an AC
reactor to the output side (U,
V, W) of the inverter.
Varispeed G7
MCCB
AC Reactor
Motor
R/L1
S/L2
T/L3
U/T1
V/T2
W/T3
Options, Peripheral Devices
Dimensions in mm