Specifications
6 Application of Encoder (PG)
15
6 Application of Encoder (PG)
The maximum frequency of the encoder (PG) output pulses that can be detected is 300 kHz.
To find the output frequency of your encoder (PG), use the following formula.
Maximum power available to drive the encoder (PG) with the PG-X2 is 200 mA. Should
your encoder (PG) require more than 200 mA, it will be necessary to provide a separate
power supply. If momentary power loss ride-through function is necessary, provide backup
capacitor or take other necessary measures. See Fig. 7.
* Backup capacitor momentary power loss recovery
Fig. 7 Connection Example with Encoder (PG) when Using Separate Power Supply
f
PG
(Hz) = × Encoder (PG) constant (pulses/rev)
Motor rotation speed (min
-1
) at max. frequency output
60
PG power supply
Signal
AC
PG-X2
IP12
TA1
IG
IP5
A (+)
A (−)
B (+)
B (−)
Z (+)
Z (−)
IG
+
+
+
PG
−
−
+12 V
0 V
TA3
0V +12V
1
2
3
4
5
6
7
8
9
10
*