Specifications

5-100
!208-240Vac Drives of 55 to 110 kW and 380-480Vac Drives of 55 to 300 kW
Table 5.5 V/F Pattern for Drive Capacity G7U2055 and higher for 208-240V Class
Parameter
No.
Name Unit Factory Setting
E1-03
V/F Pattern
Selection
–0 1 2 3 4 5 6 7
E1-04
Max. Output
Frequency
Hz 50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0
E1-05
Max. Output
Vo l t a g e
V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0
E1-06
Max. Voltage
Frequency
Hz 50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0
E1-07
Mid. Output
Frequency
V 2.5 3.0 3.0 3.0 25.0 25.0 30.0 30.0
E1-08
Mid. Output
Vo l t a g e
V 13.8 13.8 13.8 13.8 40.2 57.5 40.2 57.5
E1-09
Min. Output
Frequency
Hz 1.3 1.5 1.5 1.5 1.3 1.3 1.5 1.5
E1-10
Min. Output
Vo l t a g e
V 6.9 6.9 6.9 6.9 5.7 6.9 5.7 6.9
1. The setting shown are for 208-240Vac Drives. The values will double for 380-480Vac Drives..
2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)
Table 5.5 V/F Pattern for Drive Capacity G7U2055 and higher for 208-240V Class (continued)
Parameter
No.
Name Unit Factory Setting
E1-03
V/F Pattern
Selection
8 9 A B C D E F & FF
E1-04
Max. Output
Frequency
Hz 50.0 50.0 60.0 60.0 90.0 120.0 180.0 60.0
E1-05
Max. Output
Vo l t a g e
V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0
E1-06 Base Frequency Hz 50.0 50.0 60.0 60.0 60.0 60.0 60.0 60.0
E1-07
Mid. Output
Frequency
V 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0
E1-08
Mid. Output
Vo l t a g e
V 17.2 23.0 17.2 23.0 13.8 13.8 13.8 13.8
E1-09
Min. Output
Frequency
Hz 1.3 1.3 1.5 1.5 1.5 1.5 1.5 1.5
E1-10
Min. Output
Vo l t a g e
V 8.0 10.3 8.0 12.6 6.9 6.9 6.9 6.9
1. The setting shown are for 208-240Vac Drives. The values will double for 380-480Vac Drives.
2. These default values are for V/F or V/F with PG control methods (A1-02 = 0 or 1)