Specifications

Individual Functions
6-101
Multi-Function Contact Inputs (H1-01 to H1-10)
Multi-Function Analog Input (H3-05, H3-09)
Parameter
Number
Name
Description
Output Signal Level During
Multi-Function Analog
Output
Min.
Unit
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
U1-24
PI Feedback
Valu e
Feedback signal level when PID
control is used.
10V: Maximum Frequency
(possible for -10V thru +10V)
0.01
%
AA A A A
PID
Feedback
U1-36
PID Input
Input error to the PID regulator
(PID Setpoint - PID Feedback).
10V: Maximum Frequency
(possible for -10V thru +10V)
0.01
%
AA A A A
PID Input
U1-37
PID Output Output of the PID regulator as a
percentage of maximum
frequency (E1-04).
10V: Maximum Frequency
(possible for -10V thru +10V)
0.01
%
AA A A A
PID Output
U1-38
PID Setpoint
Setpoint of the PID regulator
(PID reference + PID bias).
10V: Maximum Frequency
0.01
%
AA A A A
PID Setpoint
Setting
Value
Function
Control Methods
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
19 PID control disable (ON: PID control disabled) Yes Yes Yes Yes Yes
30
PID control integral reset (reset when reset command is input or when stopped during
PID control)
Yes Yes Ye s Yes Ye s
31 PID control integral hold (ON: Hold) Yes Yes Yes Yes Yes
34 PID soft starter Yes Yes Yes Yes Yes
35 PID input characteristics switch Yes Yes Yes Yes Yes
Setting
Value
Function Contents (100%)
Control Methods
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
B PID feedback Maximum output frequency Yes Yes Yes Yes Yes
C PID target value Maximum output frequency Yes Yes Yes Yes Yes