Specifications

Digital Operator Functions
6-143
" Copying Parameters
The Digital Operator can perform the following three functions using the built-in EEPROM (non-volatile
memory).
Store Drive parameter set values in the Digital Operator (READ)
Write parameter set values stored in the Digital Operator to the Drive (COPY)
Compare parameter set values stored in the Digital Operator with Drive parameters (VERIFY)
!Related Parameters
Parameter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
o3-01
Copy Function
Selection
This parameter controls the
copying of parameters to and
from the Digital Operator.
0: COPY SELECT (no function)
1: INV --> OP READ - All
parameters are copied from the
Drive to the Digital Operator.
2: OP --> INV WRITE - All
parameters are copied from the
Digital Operator to the Drive.
3: OP<-->INV VERIFY -
Parameter settings in the Drive
are compared to those in the
Digital Operator.
Note: When using the copy
function, the Drive model
number (o2-04), software
number (U1-14), and control
method (A1-02) must match or
an error will occur.
0 to 3 0 NoAAAAA
Copy Function
Sel
o3-02
Copy Allowed
Selection
Enables and disables the Digital
Operator copy functions.
0: Disabled - No Digital Operator
copy functions are allowed.
1: Enabled - Copying allowed.
0 to 1 0 NoAAAAA
Read Allowable