User`s manual

5-43
5
Multi-function Contact Outputs: H2
Multi-function Contact Output Functions
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
V/f
with
PG
Open
Loop
Vector
Closed
Loop
Vector
Display
H2-01
Terminal
M1-M2
function
selection
Multi-function contact
output 1
0 to 38 0 No A A A A 40BH -
Term
M1-M2 Sel
H2-02
Terminal
M3-M4
function
selection
Multi-function contact
output 2
0 to 38 1 No A A A A 40CH -
Term
M3-M4 Sel
H2-03
Terminal
M5-M6
function
selection
Multi-function contact
output 3
0 to 38 2 No A A A A 40DH -
Term
M5-M6 Sel
Setting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
loop
Vector
Closed
Loop
Vector
0 During run (ON: run command is ON or voltage is being output) Yes Yes Yes Yes 6-74
1 Zero-speed Yes Yes Yes Yes 6-74
2
f
ref
= f
out
agree 1 (detection width L4-02 is used.)
Yes Yes Yes Yes 6-32
3
f
ref
= f
set
agree 1 (ON: Output frequency = ±L4-01, with detection width L4-02 used
and during frequency agree)
Yes Yes Yes Yes 6-32
4
Frequency detection 1 (ON: +L4-01 output frequency -L4-01, with detection
width L4-02 used)
Yes Yes Yes Yes 6-32
5
Frequency detection 2 (ON: Output frequency +L4-01 or output frequency -L4-
01, with detection width L4-02 used)
Yes Yes Yes Yes 6-32
6
Inverter operation ready
READY: After initialization or no faults
Yes Yes Yes Yes 6-75
7 During DC bus undervoltage (UV) detection Yes Yes Yes Yes 6-75
8 During baseblock (NO contact, ON: during baseblock) Yes Yes Yes Yes 6-75
9 Frequency reference source selection (ON: Frequency reference from Operator) Yes Yes Yes Yes 6-75
A Run command source selection status (ON: Run command from Operator) Yes Yes Yes Yes 6-75
B
Overtorque/undertorque detection 1 NO (NO contact, ON: Overtorque/undertorque
detection)
Yes Yes Yes Yes 6-46
C Loss of frequency reference (Effective when 1 is set for L4-05) Yes Yes Yes Yes 6-57
D Braking resistor fault (ON: Resistor overheat or braking transistor fault) Yes Yes Yes Yes 6-59
E
Fault (ON: Digital Operator communications error or fault other than CPF00 and
CPF01 has occurred.)
Yes Yes Yes Yes 6-75
F Not used. (Set when the terminal is not used.) Yes Yes Yes Yes -
10 Minor fault (ON: Alarm displayed) Yes Yes Yes Yes 6-75
11 Fault reset command active Yes Yes Yes Yes 6-75
12 Timer function output Yes Yes Yes Yes 6-95
13
f
ref
= f
set
agree 2 (detection width L4-04 is used)
Yes Yes Yes Yes 6-32
14
f
ref
= f
set
agree 2 (ON: Output frequency = L4-03, with detection width L4-04 is
used, and during frequency agree)