User`s manual

5-44
5
15
Frequency detection 3 (ON: Output frequency -L4-03, detection width L4-04 is
used)
Yes Yes Yes Yes 6-32
16
Frequency detection 4 (ON: Output frequency -L4-03, detection width L4-04 is
used)
Yes Yes Yes Yes 6-32
17 Overtorque/undertorque detection 1 NC (NC Contact, OFF: Torque detection) Yes Yes Yes Yes 6-46
18 Overtorque/undertorque detection 2 NO (NO Contact, ON: Torque detection) Yes Yes Yes Yes 6-46
19 Overtorque/undertorque detection 2 NC (NC Contact, OFF: Torque detection) Yes Yes Yes Yes 6-46
1A During reverse run (ON: During reverse run) Yes Yes Yes Yes 6-75
1B During baseblock 2 (OFF: During baseblock) Yes Yes Yes Yes 6-75
1C Motor selection (ON: Motor 2 selected) Yes Yes Yes Yes 6-76
1D During regenerative operation No No No Yes 6-76
1E Restart enabled (ON: Restart enabled) Yes Yes Yes Yes 6-58
1F
Motor overload (OL1, including OH3) pre-alarm (ON: 90% or more of the detec-
tion level)
Yes Yes Yes Yes 6-49
20 Inverter overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting) Yes Yes Yes Yes 6-60
30 During torque limit (current limit) (ON: During torque limit) No No Yes Yes 6-118
31 During speed limit No No No Yes 6-118
32
Activated if the speed control circuit (ASR) is operating for torque control. The
ASR output becomes the torque reference. The motor is rotating at the speed limit.
No No No Yes 6-118
33 Zero-servo end (ON: Zero-Servo completed) No No No Yes 6-125
37
During run 2 (ON: Frequency output, OFF: Base block, DC injection braking, ini-
tial excitation, operation stop)
Yes Yes Yes Yes 6-74
38 Drive enabled Yes Yes Yes Yes 6-76
Setting
Value
Function
Control Methods
Page
V/f
V/f
with
PG
Open
loop
Vector
Closed
Loop
Vector