User`s manual

6-32
6
Time Charts
The following table shows the time charts for each of the speed agreement functions.
Related
parameter
L4-01: Speed Agree Level
L4-02: Speed Agree Width
L4-03: Speed Agree Level +/–
L4-04: Speed Agree Width
f
ref
= f
out
Agree
f
ref
= f
out
Agree 1
f
ref
= f
out
Agree 2
f
out
= f
set
Agree
f
out
= f
set
Agree 1
(ON at the following conditions during frequency agree)
f
out
= f
set
Agree 2
(ON at the following conditions during frequency agree)
Frequency
Detection
Frequency (FOUT) Detection 1
(L4-01 > | Output frequency |)
Frequency (FOUT) Detection 3
(L4-03 > Output frequency)
Frequency (FOUT) Detection 2
(L4-01 < | Output frequency |)
Frequency Detection 4
(L4-03 < Output frequency)
L4-02
L4-02
ON
OFF
Output
Frequency or
Motor Speed
f
ref
= f
out
Agree
Frequency
Reference
Frequency
Reference
(Multi-function output setting = 2)
L4-04
L4-04
ON
OFF
Output
Frequency or
Motor Speed
f
ref
= f
out
Agree 2
Frequency
Reference
Frequency
Reference
(Multi-function output setting = 13)
L4-01
L4-02
L4-01
L4-02
ON OFF
Output
Frequency or
Motor Speed
f
out
= f
set
Agree 1
(Multi-function output setting = 3)
L4-03
L4-04
ON OFF
Output
Frequency or
Motor Speed
f
out
= f
set
Agree 2
(Multi-function output setting = 14)
L4-01
L4-02
L4-01
L4-02
ON OFF
Output
Frequency or
Motor Speed
Freq. Detection 1
(Multi-function output setting = 4)
L4-03
L4-04
ON OFF
Output
Frequency or
Motor Speed
Freq. Detection 3
(Multi-function output setting = 15)
L4-01
L4-02
L4-01
L4-02
ON
OFF
Output
Frequency or
Motor Speed
Freq. Detection 2
(Multi-function output setting = 5)
L4-03
L4-04
ON
OFF
Output
Frequency or
Motor Speed
Freq. Detection 4
(Multi-function output setting = 16)