User`s manual
10-11
10
E4-06 Motor 2 leak inductance *1
E4-07 Motor 2 rated capacity *1
F1-01 PG constant 1024
F1-02 Operation selection at PG open circuit (PGO) 1
F1-03 Operation selection at overspeed (OS) 1
F1-04 Operation selection at deviation 3
F1-05 PG rotation 0
F1-06 PG division rate (PG pulse monitor) 1
F1-07 Integral value during accel/decel enable/disable 0
F1-08 Overspeed detection level 115%
F1-09 Overspeed detection delay time 1.0 s
F1-10 Excessive speed deviation detection level 10%
F1-11 Excessive speed deviation detection delay time 0.5 s
F1-12 Number of PG gear teeth 1 0
F1-13 Number of PG gear teeth 2 0
F1-14 PG open-circuit detection delay time 2.0 s
F2-01 Bi-polar or uni-polar input selection 0
F3-01 Digital input option 0
F6-01 Operation selection after communications error 1
F6-02 Input level of external error from Communications Option Card 0
F6-03 Stopping method for external error from Communications Option Card 1
F6-04 Trace sampling from Communications Option Card 0
F6-05 Current monitor unit selection 1
F6-06 Torque reference/torque limit selection from communications option card 1
H1-01 Terminal S3 function selection 24
H1-02 Terminal S4 function selection 14
H1-03 Terminal S5 function selection
3 (0)
*2
H1-04 Terminal S6 function selection
4 (3)
*2
H1-05 Terminal S7 function selection
6 (4)
*2
H2-01 Terminal M1-M2 function selection 0
H2-02 Terminal M3-M4 function selection 1
H2-03 Terminal M5-M6 function selection 2
H3-01 Multi-function analog input terminal A1 signal level selection 0
H3-02 Gain (terminal A1) 100.0%
H3-03 Bias (terminal A1) 0.0%
H3-08 Multi-function analog input terminal A2 signal level selection 2
H3-09 Multi-function analog input terminal A2 function selection 0
H3-10 Gain (terminal A2) 100.0%
H3-11 Bias (terminal A2) 0.0%
H3-12 Analog input filter time constant 0.00 s
H3-13 Terminal A1/A2 switching 0
H4-01 Monitor selection (terminal FM) 2
H4-02 Gain (terminal FM) 100%
H4-03 Bias (terminal FM) 0.0%
No. Name
Factory
Setting
Setting