User`s manual

10-13
10
L5-02 Auto restart operation selection 0
L6-01 Torque detection selection 1 0
L6-02 Torque detection level 1 150%
L6-03 Torque detection time 1 0.1 s
L6-04 Torque detection selection 2 0
L6-05 Torque detection level 2 150%
L6-06 Torque detection time 2 0.1 s
L7-01 Forward drive torque limit 200%
L7-02 Reverse drive torque limit 200%
L7-03 Forward regenerative torque limit 200%
L7-04 Reverse regenerative torque limit 200%
L7-06 Torque limit time constant 200 ms
L7-07 Torque Limit Operation during accel/decel 0
L8-01 Protect selection for internal DB resistor (Type ERF) 0
L8-02 Overheat pre-alarm level
95 °C
*1
L8-03 Operation selection after overheat pre-alarm 3
L8-05 Input open-phase protection selection 1
L8-07 Output open-phase protection selection 0
L8-09 Ground protection selection 1
L8-10 Cooling fan control selection 0
L8-11 Cooling fan control delay time 60 s
L8-12 Ambient temperature 45 °C
L8-15 OL2 characteristics selection at low speeds 1
L8-18 Soft CLA selection 1
N1-01 Hunting-prevention function selection 1
N1-02 Hunting-prevention gain 1.00
N2-01 Speed feedback detection control (AFR) gain 1.00
N2-02 Speed feedback detection control (AFR) time constant 50 ms
N2-03 Speed feedback detection control (AFR) time constant 2 750 ms
N3-01 High-slip braking deceleration frequency width 5%
N3-02 High-slip braking current limit 150%
N3-03 High-slip braking stop dwell time 1.0 s
N3-04 High-slip braking OL time 40 s
o1-01 Monitor selection 6
o1-02 Monitor selection after power up 1
o1-03 Frequency units of reference setting and monitor 0
o1-04 Setting unit for frequency parameters related to V/f characteristics 0
o1-05 LCD Display contrast adjustment 3
o2-01 LOCAL/REMOTE key enable/disable 1
o2-02 STOP key during control circuit terminal operation 1
o2-03 User parameter initial value 0
o2-04 kVA selection 0
o2-05 Frequency reference setting method selection 0
o2-06 Operation selection when digital operator is disconnected 0
o2-07 Cumulative operation time setting 0 hr
No. Name
Factory
Setting
Setting