[Example] Store the parameters read out from the inverter, in the EEPROM inside the digital operator
.
*1 When READ is enabled (n177=1), this setting is not necessary.
*2 The setting is not necessary unless the READ prohibition is selected.
Explanation Operator display
Enable the setting of the
parameters n001 to n179.
Set parameter read prohibited
selection (n177) to read
enabled. *1
Execute read-out (READ) by
parameter copy function
selection (n176).
Set Parameter read prohibited
selection (n177) to READ
disabled. *2.
Press DSPL to light [PRGM].
Press ENTER to display the set
value.
Change the set value to 4 by
pressing or key.
Press ENTER.
Change the parameter No. to
n177 by pressing or key.
Press ENTER to display the set
value.
Change the set value to 1 by
pressing or key.
Press ENTER.
Change the parameter No. by
pressing or key.
Press ENTER to display the set
value.
Change the set value to rEd by
pressing or key.
Press ENTER.
Press DSPL or ENTER
Change the parameter No. to
n177by pressing or key.
Press ENTER to display the set
value.
Change the set value to 0 by
pressing or key.
Press ENTER.
(Can be a different parameter No.)
( Lit )
(Can be a different set value.)
(Blinks)
(Lit for one second.)
(The parameter is
displayed)
( Lit )
(Blinks)
(Lit for one second)
(The parameter displayed)
(Lit)
(Lit)
(Blinks while executing
READ)
(End is displayed after the
execution of READ is completed.)
(The parameter is
displayed.)
(Lit)
( Blinks )
( Lit for one minute )
(The parameter No. is
displayed.)