To hold acceleration or deceleration, input accel/decel hold command. The output 
frequency is maintained when the accel/decel hold command is input during 
acceleration or deceleration.
When the stop command is input during accel/decel prohibition command input, accel/
decel hold is released and operation ramps to stop.
Set multi-function input terminal selection (n050 to n056) to 16 (accel/decel hold 
command).