Instruction manual
6. Programming Features
107
 Selecting Cooling Fan Operation
In order to increase the life of the cooling fan, the fan can be set to oper-
ate only when Inverter is running
n039 = 0 (Factory setting): Operates only when Inverter is running 
(Continues operation for 1 minute after 
Inverter is stopped.)
=1: Operates with power ON
 Using MEMOBUS (MODBUS) Communications
Serial communication is available with VS-606V7 using programmable 
controller (MEMOCON series) and MEMOBUS (MODBUS). Refer to 
MEMOBUS Instruction Manual (Manual No.: TOEZ-C736-70.1) for 
details of communications.
 MEMOBUS (MODBUS) Communications
MEMOBUS system is composed of a single master (PLC) and slaves (1 
to 31 VS-606V7 units).
Communication between master and slave (serial communication) is 
controlled according to the master program with the master initiating 
communication and the slave responding.
The master sends a signal to one slave at a time. Each slave has a pre-
registered address No., and the master specifies the number and conduct 
signal communications. The slave receives the communications to 
carry out designated functions and reply to the master.
MEMOCON Series
VS-606V7
Example of RS-485
communication
VS-606V7 VS-606V7