Instruction manual
9. Specifications
197
016 0110 Min. Output Frequency 0.1 to 10.0 Hz 0.1 Hz 1.5 Hz
(Note 6)
No 55
017 0111 Min. Output Frequency Volt-
age
0.1 to 50.0 V 
(Note 2)
0.1 V 12.0 V 
(Note 2, 
6)
No 55
018 0112 Selecting Setting Unit for Ac-
celeration/deceleration Time
0, 1 - 0 No 70
019 0113 Acceleration Time 1 0.00 to 6000 s Depend on 
n018 setting
10.0 s Yes 69
020 0114 Deceleration Time 1 0.00 to 6000 s Depend on 
n018 setting
10.0 s Yes 69
021 0115 Acceleration Time 2 0.00 to 6000 s Depend on 
n018 setting
10.0 s Yes 69
022 0116 Deceleration Time 2 0.00 to 6000 s Depend on 
n018 setting
10.0 s Yes 69
023 0117 S-curve Selection  0 to 3 - 0 No 71
024 0118 Frequency Reference 1 (Mas-
ter Frequency Reference)
0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
6.00 Hz Yes 65
025 0119 Frequency Reference 2  0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
0.00 Hz Yes 65
026 011A Frequency Reference 3  0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
0.00 Hz Yes 65
027 011B Frequency Reference 4 0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
0.00 Hz Yes 65
028 011C Frequency Reference 5  0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
0.00 Hz Yes 65
029 011D Frequency Reference 6  0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/
0.1 Hz (100 
Hz or more)
0.00 Hz Yes 65
No. Register 
No. for 
Trans-
mission
Name Setting Range Setting Unit Factory 
Setting
Change
during
Opera-
tion
User 
Set-
ting
Ref. 
Page