Instruction manual
9. Specifications
201
Third Functions (Constants n080 to n119)
No. Register 
No. for 
Trans-
mission
Name Setting Range Setting Unit Factory 
Setting
Change
during
Opera-
tion
User 
Set-
ting
Ref. 
Page
080 0150 Carrier Frequency Selection 1 to 4, 7 to 9 - (Note 4) No 81
081 0151 Momentary Power Loss 
Ridethrough Method
0 to 2 - 0 No 70
082 0152 Automatic Retry Attempts 0 to 10 times - 0 No 75
083 0153 Jump Frequency 1 0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/0.1 
Hz (100 Hz 
or more)
0.00 Hz No 74
084 0154 Jump Frequency 2 0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/0.1 
Hz (100 Hz 
or more)
0.00 Hz No 74
085 0155 Jump Frequency 3 0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/0.1 
Hz (100 Hz 
or more)
0.00 Hz No 74
086 0156 Jump Frequency Range 0.00 to 
25.50 Hz
0.01 Hz 0.00 
Hz
No 74
087 0157 Cumulative operation time 
function selection 
*9
0, 1 - 0 No -
088 0158 Cumulative operation time 
*9
0 to 6550 1 = 10H 0H No -
089 0159 DC Injection Braking Current 0 to 100% 1% 50% No 76
090 015A DC Injection Braking Time at 
Stop
0.0 to 25.5 s 0.1 s 0.5 s No 86
091 015B DC Injection Braking Time at 
Startup
0.0 to 25.5 s 0.1 s 0.0 s No 76
092 015C Stall Prevention During Decel-
eration
0, 1 - 0 No 103
093 015D Stall Prevention Level During 
Acceleration
30% to 200% 1% 170% No 100
094 015E Stall Prevention Level During 
Running
30% to 200% 1% 160% No 103
095 015F Frequency Detection Level 0.00 to 400.0 
Hz
0.01 Hz 
(less than 
100 Hz)/0.1 
Hz (100 Hz 
or more)
0.00 Hz No 73