Instruction manual
3. Mounting
27
• The same space is required horizontally and vertically and 
right and left for both Open Chassis (IP00, IP20) and 
Enclosed Wall-mounted (NEMA 1) Inverters.
• Always remove the top and bottom covers before install-
ing a 200 or 400 V Class Inverter with an output of 5.5/7.5 
kW in a panel.
 Mounting/Removing Components
Removing and Mounting the Digital Operator and Covers
 Removing the Front Cover
Use a screwdriver to loosen the screw 
on the front cover and then remove it 
in direction 1. Then press the right 
and left sides in direction 2 and lift the 
front cover in direction 3.
 Mounting the Front Cover
Mount the front cover by reversing 
the order of the above procedure for 
removal.
 Removing the Terminal Cover
• Inverters with Width of 108 mm, 
140 mm or 170 mm
After removing the front cover, 
press the right and left sides of the 
terminal cover in direction 1 and 
lift the terminal cover in direction 
2.
NOTE