6 Initial Setup
Before starting communications between the Inverter and the MECHATROLINK master, set
the following constants as required.
* If running or stopping the Inverter from MECHATROLINK, set n003 to
3. If setting the frequency from MECHATROLINK, set n004 to 9. For
details, refer to the VS-606 V7 Series Instruction Manual (TOE-S606-
11).
Constant
No.
Name Description Default
n003 Operation
Method Selec-
tion
0: Digital Operator
1: Control-circuit terminal
2: MEMOBUS communications
3: Communications Card (optional)
0
n004 Frequency
Reference
Selection
0: Digital Operator
1: Frequency reference 1 (n024)
2: Control circuit terminal (0 V to 10 V)
3: Control circuit terminal (4 mA to 20 mA)
4: Control circuit terminal (0 mA to 20 mA)
5: Pulse train
6: MEMOBUS communications
7: Digital Operator circuit terminal (0 to 10 V)
8: Digital Operator circuit terminal (4 to 20 mA)
9: Communications Card (optional)