Commercial Dehumidifier Please read the manual carefully before using the unit EEC Ed cle USER MANUAL rer CEE
BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.
FOR CUSTOMERS Thank you for purchasing our dehumidifier. McGuffey wishes our products and services can bring convenience to your work and life. Woe highly recommend you to keep the manual for reference, In case you encounter unexpected Issues using this unit. Please read the manual carefully to ensure proper use of the dehumidifier. Our dehumidifiers are widely used In family bedrooms, bathrooms, basements, offices and storage rooms, ete.
MCGUFFEY CATALOG Precaution For Use. Product Structure, Control INEBRIATES. overseas seas ne sas insane sas sans s ans ns naan 03 Operation HUTCHINSON comic mmmermereseoieerasosoarans 04 Cleaning and 12 Common Faults and Solutions o.com moment. 1% SABINA NOB. nests inset rests seniors 15 Technical Parameters oceans 16 Warranty & Contact Information. vam roommate ean 17 Statement The graphics and functions provided in this manual may not be the same as the actual product.
PRECAUTIONS FOR USE + Install the dehumidifier on flat surface to minimize vibration and/or noise. » Inspect the power cord before use. Never operate the dehumidifier when the power cord or plug is damaged. = Insert the three-prong plug on the power cord inch a matching electrically grounded outlet (120V/60Hz, 15A at least). Do not use an adapter. Never cut off the third prong. Do not use an extension cord. « Do not operate the dehumidifier in standing water. Keep motor and wiring dry.
PRODUCT STRUCTURE 1.Handle Bar 2 Handle 3. Wheels 4.Control Panel 5.Air Inlet Airing Filter wow = air Outlet 2.Pump Drain Outlet 3.Cord Winder 4.Power Cord Port 5.Pump Reservoir 6.
CONTROL INTERFACE 4.
OPERATION INSTRUCTION insetting Setting Humidity # The humidity level can be set within a range of 10%RH to 98%RH in 1% increments. +» When it starts work, it will first automatically detect and show the room's humidity. Press the "UP" button to change the humidity selection in 1% increments.Press "DOWN" to make it decrease by 1%RH. "G2" Flash and show the setting humidity. + When the humidity level is set at 30%RH, the dehumidifier will work at continuous dehumidifying mods.
OPERATION INSTRUCTION Auto Defrost When the frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears. Auto-Restart If the dehumidifier shuts off unexpectedly due to power being cut, the dehumidifier will restart with the previous function setting automatically when the power resumes. Auto Drain Thanks to the built-in pump, the dehumidifier will drain the condensation water automatically.
OPERATION INSTRUCTION 3. Display Status Description « When the machine is defrosting, the defrost indicator :: coercer will be flashing, defrosting end the light goes out. # When the pump is draining, PUMP Indicator = ewe will be flashing. + When set or check the timer,the timer indicator me will be flashing. # When the dimer is setup properly the indicator ner = will light up, light goes out when timer function is not activated.
OPERATION INSTRUCTION 4.Error & Protection Code EP Water pump failure 1.Tum off the dehumidifier and unplug it; 2. Find the gravity drain outlet at the bottom of the dehumidifier and connect the emergency hose to drain; 3.After emptying the reservoir, close the gravity drain outlet; 4.Connect the pump drain hose; Re-plug and start the dehumidifier to check the pump function. EC Control Pane! Failure The dehumidifier will not be ready for operation.
OPERATION INSTRUCTION Attention When the machine signals the alarm, it will flash or display the alarm, in case there will be multiple errors on the unit, it will display the errors in turn. When one of above malfunctions occurs, the buzzer will alarm for a few seconds, press any key during the alarm to release the alarm sound. If the malfunction is still present, please don't hesitate to contact McGuffey Customer Service email: for help.
OPERATION INSTRUCTION S.installing the Handle 1. Take out 4 screws and a handle from the accessories, and put the handle into the groove at the back of the humidifier, making the screws correspond to the screw holes. 2.Tighten all the four screws on the hands respectively, the installation is finished. Put the handle into the groove at Tighten all the four screws, the back of the dehumidifier, complete the installation. making the 4 screws correspond to the screw hole.
OPERATION INSTRUCTION 8.Continuous Drainage This dehumidifier has an internal pump that will automatically drain the condensate out via the long drain hose. Before truing on the dehumidifier, make sure the hose has been connected to the drain outlet properly. 1. Uncoil the entire hose; 2. Attach the hose to the drain outlet; 3.
OPERATION INSTRUCTION 7. Manual Drainage In power-disconnected status, tilt the dehumidifier as the figure shown, pull out the rubber plug and put the dehumidifier straight to drain the sewage in the water tank.
CLEANING AND MAINTENANCE WARNING: Tum the dehumidifier off and remove the plug from the wall outlet before cleaning A-Cleaning the Dehumidifier Clean the dehumidifier housing with a soft damp cloth. Do not submerge or place water on the dehumidifier or control panel. Water may damage the electronic components of the dehumidifier. Do not use chemical solvents such as benzene, alcohol, gasoline or other heavy-duty cleaners. The surface may become damaged or deformed.
COMMON FAULTS AND SOLUTIONS Check the information below for troubleshooting steps that will save you time to resolve issues that may happen with the unit. The list includes most issues but not the results of defective unit, crafts or materials in the unit. If all the troubleshooting steps have been exhausted and issue is stilling occurring, feel free to get in touch with McGuffey Customer Service to get further assistance.
COMMON FAULTS AND ie is 6 Place the dehumidifier on The dehumidifier is titled, | Fla the de . Drain hose connection Is | Make sure the drain hose Leaking not tight connection is tight The drain hose is blacked | Check hose for restrictions JOR.
SAFETY NOTE &) When using, make sure doors ~~ 3 Do not Insert thin rods and hard £3 When using, please keep the and windows are closed to get objects into the fuselage to machine away from heating the bast humidity removal affect. avoid malfunction and danger. fum ace, electric kettle and sources. £3 When cleaning the dehumidifier {3 Please do not put objects around {If do not usa the product fora fuselage, please use wet cloth tha body.
TECHNICAL PARAMETERS MODEL NO. PDGT701BD POWER SOURCE 120V~60Hz RATED 1150W RATED 103A MOISTURE 50 Pints/Day MOISTURE 90 Pints/Day MOISTURE REMOVAL 150 Pints/Day MOISTURE 180 Pints/Day INPUT 610W INPUT 5.5A 1.60 liters/kWh MOTOR FLA 0.92A MOTOR COMPRESSOR REFRIGERANT (570g) MAXIMUM ALLOWABLE PRESSURE 6.2MPa HIGH PRESSURE pampas LOW PRESSURE 1.7MPa £\ WARNING: This product can expose you to chemicals including Polystyrene and its compounds, which is known to the State of California to cause cancer and birth
WARRANTY AND CONTACT US Warranty McGuffey offers a 12-month warranty to all of our products together with the original proof of purchase when a deface occurred, including those newly purchased and unused, from McGuffey or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.