 normal(1), 
 alarm(2) 
 } 
 ACCESS read-only 
 STATUS mandatory 
 DESCRIPTION 
 "A bit error rate alarm will be generated if the level 
 of BER is at or above 10^-3, i.e. if bitErrorRate is 
 equal to or greater than 100000." 
 ::= { link_cx_status 11 } 
-- link_cx_test group 
rfTxAttenuateTimer OBJECT-TYPE 
 SYNTAX INTEGER (0..1800) 
 ACCESS read-write 
 STATUS mandatory 
 DESCRIPTION 
 "To temporarily enable Tx attenuation by 40 dB, write the number of 
 seconds to this timer. When the timer counts down to 0, Tx attenuation 
 will return to its normal unattenuated state. Writing to this timer 
 has no effect if rfTxAttenuateControl is set to enable because in 
 that case the transmitter is already attenuated." 
 ::= { link_cx_test 1 } 
-- link_cx_reboot group 
softwareVersionBank1 OBJECT-TYPE 
 SYNTAX DisplayString (SIZE (0..15)) 
 ACCESS read-only 
 STATUS mandatory 
 DESCRIPTION 
 "The software version in bank one." 
 ::= { link_cx_reboot 1 } 
softwareVersionBank2 OBJECT-TYPE 
 SYNTAX DisplayString (SIZE (0..15)) 
 ACCESS read-only 
 STATUS mandatory 
 DESCRIPTION 
 "The software version in bank two." 
 ::= { link_cx_reboot 2 } 
bootedUsingBankNumber OBJECT-TYPE 
 SYNTAX INTEGER { 
 bankOne(1), 
 bankTwo(2) 
 } 
 ACCESS read-only 
 STATUS mandatory 
 DESCRIPTION 
 "The software bank from which the unit booted." 
 ::= { link_cx_reboot 3 } 
bootUsingBankNumber OBJECT-TYPE 
 SYNTAX INTEGER { 