Exe/Devon/County Double Freestanding Double Sided Stove USER INSTRUCTIONS For use in Great Britain and Eire. This product is suitable for use in the stated countries. To install the product in other countries it is essential to obtain translated instructions and in some cases the product may require modification. Contact Yeoman Stoves to obtain further information.
FOR YOUR RECORDS To assist us in any Guarantee claim please complete the following information:- Dealer appliance was purchased from Name:...................................................................................................................................................................................... Address:................................................................................................................................................................................... ..
SERVICE RECORDS 1st SERVICE 2nd SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service Due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Next Service Due: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING INSTRUCTIONS Before using this appliance, please read these instructions fully. SERIAL NUMBER 1. GENERAL 1.1 1.8 This stove is designed for domestic heating and should only be used for this purpose, and in accordance with the manufacturers operating instructions. This number will be required when ordering spare parts or making warranty claims. It is found on the DATA PLATE, located on the underside of the stove.
OPERATING INSTRUCTIONS DOOR HANDLE Fuel Consumption Description To Open and Close Drop door tool over knob to fit. Rotate 1/ 2 turn anti-clockwise to open. Rotate 1/ 2 turn clockwise to close. Lift up door tool to remove Open Kg/Hour Wood (300mm long) Kg/Hour Briquetted Smokless Fuel Exe Double Double 3.5 1.2 Devon Single Double 3.5 1.6 Devon Double Double 4.5 2.2 County Single Double 5.1 2.3 County Double Double 6.
OPERATING INSTRUCTIONS 4.9 Do not re-fuel the stove above the level of the log guards. 5.10 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the stove. It is not recommended to load large amounts of fuel and burn with the Primary Air Control on low settings for long periods of time as this will reduce the effectiveness of the glass cleaning effect of the airwash.
OPERATING INSTRUCTIONS 8.3 Backpuffing 7. OVER FIRING 7.1 Do not use the appliance at maximum output for prolonged periods of time, or over fill the firebox with fuel, as this could result in over-firing. If the connecting fluepipe, appliance flue collar or top plate glow red with heat the appliance is being over fired and the air controls should be closed to reduce the output. 7.
OPERATING INSTRUCTIONS Damp / Rainy days – These sometimes result in problems when lighting and maintaining the fire, due to the lower flue temperatures and smaller difference between indoor and outdoor temperatures reducing the flue draught. Also, rain water running down the inside of the chimney reduces the flue temperatures.
MAINTENANCE and SERVICING See chart on page 10 for common spare parts referred to in this section. For a complete list of spare parts and accessories contact your Yeoman dealer for the Stovax Fireplace, Stove & Hearth Accessories Brochure or call 01392 474011 1. GENERAL CLEANING 4.3 Clean the internal surfaces, baffles and grate parts of the stove using a wire brush and scraper as required and check the parts for any damage. Replace any damaged parts.
MAINTENANCE and SERVICING This is a list of the maintenance products you may need to use Task Product Name Glass Cleaning Stove glass cleaner 500ml – wipe on Stove glass cleaner 500ml – Spray on Preventing build-up Protector (15 sachets) of creosote in flue Protector (1kg tub) 4103 2020 2021 Repainting Yeoman Black (400ml aerosol) YM-V00971 Protecting your hands Door sealing rope Heat resistant leather gloves 14mm Black rope seal – (handy pack) 7000 YM-E00007 PR7550 5000 14mm Black rope seal
MAINTENANCE and SERVICING 6.5 Raise the other end of the baffle plate and attach the baffle extension tubes to the baffle pins, lower the baffle plate onto these tubes. 6.14 The baffle system is designed to give safe and efficient operation of the stove. Replace any damaged baffles immediately. 6.6 Centre the baffle plate. 6.15 Do not modify the baffle system. County (double depth, double sided models only) Two piece baffle 7.
MAINTENANCE and SERVICING 7.6 Fit only Yeoman ceramic glass, which is suitable to use in high temperature applications. 7.7 Using the stove with a damaged door glass could cause dangerous fumes to enter the room, or the stove to overfire, resulting in damage. If you require help, your local Yeoman dealer will be able to carry out all of your service and maintenance requirements for a reasonable cost. 9. ADJUSTING DOOR CATCH (ALL MODELS) 8. FITTING A NEW DOOR SEAL 8.
BASIC SPARE PARTS LIST 2 For Devon/County SINGLE double 1 3 4 5 6 7 11 8 12 13 9 10 For COUNTY SINGLE double For DEVON SINGLE double Diagram No. Part No. Description Diagram No. Part No.
BASIC SPARE PARTS LIST 2 For EXE/devon Double double 1 3 4 5 6 7 11 8 12 13 9 10 For DEVON Double double For EXE Double double Diagram No. Part No. Description Diagram No. Part No.
BASIC SPARE PARTS LIST 2 For County DOUBLE double 1 3 4 5 6 7 11 12 14 8 9 13 10 For County DOUBLE double Diagram No. Part No.
BASIC SPARE PARTS LIST For exe/devon/county 1 door 1 10 2 3 4 6 5 9 7 11 8 Common parts For exe/Devon/county 1 door For exe 1 door Diagram No. Part No. Description Diagram No. Part No. Description 1 4670 14mm Rope Seal Black 4 GL0252 2 YM-F00001 M5 x 8 Machine Screw Stove Glass Devon/Exe CE 1 Door Large 3 YM-C00353 Standard Glass Clip 5 4974 3mm Rope Seal Black 6 YM-F00010 M10 x 35HH Spinner Bolt Diagram No. Part No.
BASIC SPARE PARTS LIST For exe/devon/county 2 door 1 6 18 7 2 3 17 5 13 15 4 8 14 16 12 11 10 For exe 2 door 9 Diagram No. Part No. Description 4 GL0251 Stove Glass Devon/Exe CE 6 Sided 5 YM-YM81001 Devon/Exe CE Twin Door Cross RH 6 YM-YM81101 Devon/Exe CE Twin Door Cross LH 11 YM-YA81057 Exe Air Slider Inner Plate Assembly 12 YM-C81087 Exe Air Slider Back Plate Common parts For exe/Devon/county 2 door For Devon 2 door Diagram No. Part No. Description Diagram No.
A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.com www.yeoman-stoves.co.