LTE4815 Spec Sheet
LTE4815_
Electric Double Oven Slide-In
DIMENSIONS/CLEARANCES/WEIGHT
Cabinet Width (in) 30"
Overall Depth (in) - including handle 28 15/16"
Overall Width (in) 29 7/8"
Oven Interior Dimensions (Upper) (in) (W x H x D) 24 13/16" x 10 13/16" x 20"
Oven Interior Dimensions (Lower) (in) (W x H x D) 24 13/16" x 14 1/4" x 20"
Height to Cooking Surface (in) 36"
Carton Dimensions (in) (W x H x D) 31 31/32" x 51" x 30 17/32"
POWER/RATINGS
Amp at 208V / 240V 55.8A / 64.6A
kW at 208V / 240V 11.6kW / 15.5kW
LG COOKING
HOME APPLIANCES
QUICK INSTALL & CLEARANCES
For full installation directions/clearances please refer to 
the corresponding User Manual and Installation Guide.
IMPORTANT
DIMENSIONS AND CLEARANCES
ELECTRICAL REQUIREMENTS
36"
(91.4 cm)
29.8"
(75.7 cm)
24"
(60.9 cm)
Cabinet
Cabinet 
opening
A
Acceptable 
electrical 
outlet area
3" (7.6 cm)
24"
(60.9 cm)
3" (7.6 cm)
25"
(63.5 cm)
Normal counter 
top depth
36"
(91.4 cm)
Counter 
top height
4"
(10 cm)
9"
(23 cm)
9"
(23 cm)
4"
(10 cm)
Wall
Center
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
2.5" 
(6.3 cm)
A
  = 30" (76.2 cm)
•
This appliance must be installed and grounded on a branch circuit by a 
qualied technician in accordance with the National Electrical code ANSI/
NFPA NO. 70 - latest edition. 
•
All wiring should conform to Local and NEC codes. This range requires a single-
phase, 3 wire, A.C 120/208 V or 120/240 V 60 Hz electrical system. Use only a 
3-conductor or a 4-conductor UL - listed range cord with closed-loop terminals, 
open-end spade lugs with upturned ends or similar termination. Do not install the 
power cord without a strain relief. 
•
A range cord rated at 40 amps with 120/240 minimum volt range is required. 
If a 50 amp range cord is used, it should be marked for use with 13/8" diameter 
connection openings. This appliance may be connected by means of a conduit or 
power cord. If a conduit is being used, check the Owners Manual for 3 wire conduit 
connections or 4 wire conduit connections.
▲
! 
WARNING
•
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be 
moved if servicing is ever necessary.
•
The power supply cord and plug should not be modied. If it will not t the outlet, 
have a proper outlet Installed by a qualied electrician.
•
Using an extension cord to connect the power is prohibited. Connect the power 
cord and plug directly.
•
Electrical ground is required on this appliance.
•
Make sure that the power cord is not pinched by the range or heavy objects. 
Failure to do so can result in serious burns or electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified 
rating of 
power 
supply-
cord kit, 
amperes
Diameter (inches) 
of Range 
connection 
Opening
120/240 
volts
3-wire
120/208 
volts
3-wire
Power 
cord
Conduit
 8,750 - 
16,500
16,501 - 
22,500
 7,801 - 
12,500
12,501 - 
18,500
40 or 50A
50
1 
3
/
8
" 
1 
3
/
4
"
1 
1
/
8
" 
1 
3
/
8
"
4 Wire 
receptacle 
(14-50R)
3 Wire 
receptacle 
(10-50R)
MINIMUM DIMESIONS
*  30” (76.2 cm) minimum clearance between the top of the cooking surface 
and the bottom of an unprotected wood or metal cabinet; or 
24” (60.9 cm) minimum when bottom of wood or metal cabinet is protected 
by not less than 1/4”(6.4 cm) ame retardant millboard covered with not less 
than no. 28 MSG sheet steel, 0.015” (0.381 mm) stainless steel, 0.024” 
(0.610 mm) aluminum or 0.020” (0.508mm) copper.
** 15” (38.1 cm) minimum 
between countertop and 
adjacent cabinet bottom.
30"
(76.2 cm)
*30" (76.2 cm)
Minimum
**15"
(38.1 cm)
36"
(91.4 cm)
© 2018 LG Electronics USA, Inc. All rights reserved. "LG Life’s Good" is a registered trademark of LG Corp. All other product and brand names are trademarks or registered trademarks of their respective owners. Design, features and specifications are subject to 
change without notice. Non-metric weights and measurements are approximate. Some features may require Internet access. Content and services may vary by product and are subject to change without notice. 8/22/18


