User Manual

IM 01E20D01-01E
6-45
6. OUTLINE
AXF Standard, AXF015-AXF125, Sanitary for Union Connection, PFA Lining
Integral Flowmeter Remote Flowtube Integral Flowmeter Remote Flowtube
Unit : mm (approx. inch)
F35.EPS
111(4.37)
48
(1.89)
70
(2.76)
73
(2.87)
154(6.06)
49
(1.93)
ø86(3.38)
28(1.1)
51.5
51.5
(2.03)
(2.03)
197(7.76)*
1
66*
1
ø128(5.04)
Hr
H1
Hi
L
Ground Terminal
(M4)
Ground Terminal (M4)
(ød)
øD
Adapter for union
connection
H
FG
øA
øB
ød
øE
øC
øA
øB
ød
øE
øF
H
G
øC
3
F
H
G
øA
øB
øC
ød
øE
Process
Connection
JKB (ISO2853 Union)
Nominal
Size
15
70
(2.76)
16
(0.63)
20
(0.79)
16
(0.63)
18
(0.71)
25.8
(1.02)
RD34
×1/8
50
(1.97)
F9811
KR
25
70
(2.76)
22.2
(0.87)
30
(1.18)
26
(1.02)
30
(1.18)
39.8
(1.57)
RD52
×1/6
50
(1.97)
F9811
KS
32
70
(2.76)
29.4
(1.16)
36
(1.42)
32
(1.26)
36
(1.42)
45.8
(1.80)
RD58
×1/6
50
(1.97)
F9811
KT
40
83
(3.27)
34.6
(1.36)
42
(1.65)
38
(1.50)
42
(1.65)
51.8
(2.04)
RD65
×1/6
50
(1.97)
F9811
KU
50
96
(3.78)
47.6
(1.87)
54
(2.13)
50
(1.97)
54
(2.13)
63.8
(2.51)
RD78
×1/6
50
(1.97)
F9811
KV
65
114
(4.49)
59.5
(2.34)
70
(2.76)
66
(2.60)
71
(2.80)
80.8
(3.18)
RD95
×1/6
50
(1.97)
F9811
KW
80
126
(4.96)
72.3
(2.85)
85
(3.35)
81
(3.19)
85
(3.35)
94.8
(3.73)
RD110
×1/4
60
(2.36)
F9811
KX
100
152
(5.98)
97
(3.82)
104
(4.09)
100
(3.94)
104
(4.09)
113.8
(4.48)
RD130
×1/4
60
(2.36)
F9811
KY
125
180
(7.09)
123
(4.84)
129
(5.08)
125
(4.92)
130
(5.12)
141.8
(5.58)
RD160
×1/4
65
(2.56)
F9811
KZ
øA
øB
øC
ød
øE
øF
G
H
Parts No.
15
70
(2.76)
16
(0.63)
18
(0.71)
15.2
(0.60)
21.2
(0.83)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LA
25
70
(2.76)
22.2
(0.87)
25.6
(1.01)
22.6
(0.89)
29.2
(1.15)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LB
32
70
(2.76)
29.4
(1.16)
34.3
(1.35)
31.3
(1.23)
38.2
(1.50)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LC
40
83
(3.27)
34.6
(1.36)
38.6
(1.52)
35.6
(1.40)
42.7
(1.68)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LD
50
96
(3.78)
47.6
(1.87)
51.6
(2.03)
48.6
(1.91)
56.2
(2.21)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LE
65
114
(4.49)
59.5
(2.34)
64.1
(2.52)
60.3
(2.37)
69.9
(2.75)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LF
80
126
(4.96)
72.3
(2.85)
76.7
(3.02)
72.9
(2.87)
82.6
(3.25)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LG
100
152
(5.98)
97
(3.82)
102.5
(4.04)
97.6
(3.84)
108.7
(4.28)
13.5
(0.53)
3
(0.12)
50
(1.97)
F9811
LH
JDB (DIN 11851 Union)
JSB (SMS1145 Union)
25
70
(2.76)
22.2
(0.87)
25.4
(1.00)
22.5
(0.89)
32
(1.26)
11
(0.43)
RD40
×1/6
50
(1.97)
F9811
LK
32
70
(2.76)
29.4
(1.16)
32
(1.26)
29.6
(1.17)
40
(1.57)
13
(0.51)
RD48
×1/6
50
(1.97)
F9811
LL
40
83
(3.27)
34.6
(1.36)
38.1
(1.50)
35.5
(1.40)
48
(1.89)
15
(0.59)
RD60
×1/6
50
(1.97)
F9811
LM
50
96
(3.78)
47.6
(1.87)
51
(2.01)
48.5
(1.91)
61
(2.40)
15
(0.59)
RD70
×1/6
50
(1.97)
F9811
LN
65
114
(4.49)
59.5
(2.34)
63.5
(2.50)
60.5
(2.38)
73.5
(2.89)
19
(0.75)
RD85
×1/6
50
(1.97)
F9811
LP
80
126
(4.96)
72.3
(2.85)
76.2
(3.00)
72.9
(2.87)
86
(3.39)
19
(0.75)
RD98
×1/6
50
(1.97)
F9811
LQ
100
152
(5.98)
97
(3.82)
102.5
(4.04)
97.6
(3.84)
120
(4.72)
30
(1.18)
RD132
×1/6
65
(2.56)
F9811
LR
*1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the
figure.
*2: When option code DHC is selected, waterproof glands and a 30m long cable are
attached. Add 9.5kg (20.9lb) to the weight in the table.
AXF015
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125
H
D
E
F
G
N
P
1
2
N
AL1
N
J
J
J
K
D
S
B
B
B
1
JKB:
JDB:
JSB:
Adapters for union connection
(2.6)
*3: D, E, F, G; Integral Flowmeter,
N, P; Remote Flowtube
*3
Max. Height
Hr
Hi
Max. Height
Weight kg (lb)
Height H1
Size code
Process Connection JKB / JDB / JSB
Size
Lining code
Face-to-face
length
L
Outside dia.
Inside dia.
ø
D
ø
d
JDB
JSB
JKB
JDB
JSB
JKB
Model
Remote
Flow
tube
Integral
Flowmeter
Remote
Flow
tube
Integral
Flowmeter
015
15
(0.5)
A
166
(6.55)
166
(6.55)
73
(2.87)
15.2
(0.60)
16
(0.63)
98
(3.86)
222
(8.74)
2.6
(5.7)
260
(10.24)
4.3
(9.5)
025
25
(1)
A
166
(6.55)
166
(6.55)
166
(6.55)
73
(2.87)
22.6
(0.89)
26
(1.02)
22.5
(0.89)
98
(3.86)
222
(8.74)
2.6
(5.7)
260
(10.24)
4.3
(9.5)
032
32
(1.3)
A
166
(6.55)
166
(6.55)
166
(6.55)
73
(2.87)
31.3
(1.23)
32
(1.26)
29.6
(1.17)
98
(3.86)
222
(8.74)
2.7
(6.0)
260
(10.24)
4.4
(9.7)
040
40
(1.5)
A
166
(6.55)
166
(6.55)
166
(6.55)
86
(3.39)
35.6
(1.40)
38
(1.50)
35.5
(1.40)
111
(4.37)
235
(9.25)
3
(6.6)
273
(10.73)
4.7
(10.4)
050
50
(2)
A
176
(6.94)
176
(6.94)
176
(6.94)
99
(3.90)
48.6
(1.91)
50
(1.97)
48.5
(1.91)
129
(5.08)
253
(9.96)
3.8
(8.4)
291
(11.44)
5.5
(12.1)
065
65
(2.6)
A
196
(7.73)
196
(7.73)
196
(7.73)
117
(4.61)
60.3
(2.37)
66
(2.60)
60.5
(2.38)
147
(5.79)
271
(10.67)
4.9
(10.8)
309
(12.17)
6.6
(14.6)
080
80
(3)
A
216
(8.52)
236
(9.31)
216
(8.52)
129
(5.08)
72.9
(2.87)
81
(3.19)
72.9
(2.87)
157
(6.18)
281
(11.06)
5.9
(13.0)
319
(12.54)
7.6
(16.8)
100
100
(4)
A
246
(9.70)
266
(10.49)
276
(10.88)
155
(6.10)
97.6
(3.84)
100
(3.94)
97.6
(3.84)
183
(7.20)
307
(12.09)
8.2
(18.1)
345
(13.56)
9.9
(21.8)
125
125
(5)
A
326
(12.85)
183
(7.20)
125
(4.92)
212
(8.35)
336
(13.23)
13
(28.7)
374
(14.70)
14.7
(32.4)
*
2
Weight kg (lb)
* No infra-red switches are furnished