User Manual

IM 01E20D01-01E
6-32
6. OUTLINE
Table of Optional Specifications (Size 2.5 mm (0.1 in.) to 400 mm (16 in.)) (continued)
Standard
$90-degree rotation $180-degree rotation %90-degree rotation
Optional Code RC
Optional Code RA Optional Code RB
Integral Flowmeter
Remote Flowtube
Electrical
Connection
Indicator
Electrical
Connection
Indicator
Electrical
Connection
Electrical
Connection
*1:
*3: Allowable temperature and pressure with the optional code BCC or BSC (only for Gaskets:Chloroprene rubber) are equivalent to Valqua #2010.
*4: Allowable temperature and pressure with the optional code BCF or BSF (only for Gaskets:PTFE-sheathed non-asbestos) are equivalent to Valqua #7030 (S).
*5: Special gaskets are inserted between the flowtube and the grounding ring or grounding electrode.
*6: Enhanced dual frequency excitation is not available for models with calibration code C (High Grade Accuracy).
*7: Applicable only for Australia, New Zealand, Singapore and India.
*8: Select optional code G12 or G11 when TIIS Flameproof type with wiring using a flameproof packing adapter. Available only for JIS G1/2 female electric connection.
*9: The TIIS flameproof type is only available for AXF***C-P (remote flowtube for combined use with AXFA14).
*10: In the case of Fieldbus communication type, optional codes C1, C2, C3, EM and G11 are unable to select.
T26-4.EPS
*2: When specifying the optional code BCC or BSC for a PFA
or ceramics lining, it is advisable to specify the optional
code GA, GC, or GD at the same time to prevent potential
leakage caused by the difference in elasticity between the
flowtube and chloroprene gaskets. Refer to description of
“Gasket” in the “Wetted Part Material”.
Code
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Integral
Flowmeter
Submersible
Sanitary
Applicable Model
General
Item
Specifications
Five-point Calibration
in User-specified
Span
A flow test near 0, 25, 50, 75, and 100% of the user-specified span is
performed instead of the flow test of the standard 2m/s span and a test
certificate (QIC) is submitted. Specify the span (100% flow span) whose
corresponding flow velocity lies between 0.5 to 10 m/s (0.8 to 10m/s for
sizes 32, 65, and 125mm) and that is less than the maximum line capacity.
Selectable range of flow rate span is showing below.
Selectable range of flow rate span : m
3
/h
(Flow rate span velocity : m/s)
0.009 (0.5) to 0.05 (2.83)
0.036 (0.5) to 0.2 (2.83)
0.15 (0.5) to 0.96 (3.40)
0.32 (0.5) to 2.8 (4.40)
0.89 (0.5) to 11 (6.22)
2.32 (0.8) to 28.9 (10.00)
2.27 (0.5) to 28 (6.30)
3.54 (0.5) to 56 (7.92)
9.56 (0.8) to 80 (6.70)
9.05 (0.5) to 126 (6.96)
14.2 (0.5) to 190 (6.72)
35.3 (0.8) to 300 (6.79)
31.9 (0.5) to 380 (5.97)
56.6 (0.5) to 670 (5.92)
88.4 (0.5) to 1000 (5.66)
128 (0.5) to 1200 (4.72)
174 (0.5) to 1200 (3.47)
227 (0.5) to 1350 (2.98)
Size : mm
(in.)
2.5 (0.1)
5 (0.2)
10 (0.4)
15 (0.5)
25 (1)
32 (1.25)
40 (1.5)
50 (2)
65 (2.5)
80 (3)
100 (4)
125 (5)
150 (6)
200 (8)
250 (10)
300 (12)
350 (14)
400 (16)
 SC
Explosion proof
FM Approval
FM Explosion proof
See “HAZARDOUS AREA CLASSIFICATION”
––––FF1
IECEx
Certification (*7)
IECEx Explosion proof
See “HAZARDOUS AREA CLASSIFICATION”
––––SF2
TIIS Certification
TIIS Flameproof
See “HAZARDOUS AREA CLASSIFICATION”
–– (*9) JF3
Flameproof packing
adapter for TIIS
Flameproof Type (*8)
Two flameproof packing adapters
––––G12
One flameproof packing adapter and one blind plug.
Available for integral flowmeter and only when a four-wire cable is used for
power input and signal output with a DC power supply.
––(*10) G11
AXF***G-
D
E
F
G
AXF***G-
N
P
AXF***C-
D
E
F
G
AXF***C-
N
P
AXF***W-
N
P
AXF***H-
D
E
F
G
AXF***H-
N
P
CSA Certification
CSA Explosion proof, Dual Seal
See “HAZARDOUS AREA CLASSIFICATION”
––––CF1
: Available –: Not available
ATEX Certification
ATEX Explosion proof
See “HAZARDOUS AREA CLASSIFICATION”
––––KF2