User Manual

IM 01E20C02-01E
8-7
8. OPERATION VIA HART COMMUNICATOR
8.4.6 Menu Tree for DD (HART 5)
1 Device setup
1 Process Variables PV % rnge
PV
PV AO
Totl
Reverse Totl
Dif Totl
2 Diag/Service
1 Test/Status
1 Status
Status group 1(System alarms)
Status group 3(Process alarms)
Status group 5(Setting alarms)
Status group 6(Setting alarms)
Status group 7(Setting alarms)
Status group 8(Warnings)
2 Self test
1 Auto Zero Exe
2 Magflow Zero
3 D/A trim
4 Scaled D/A trim
2 Adjustment
3 Output Test
1 Loop test 4mA
20mA
Other
End
R
R
R
R
R
R
A10
A20
A21
A30
A31
A32
P
P
P
P
P
P
R
R
R
R
R
R
M10/B50
M11
W
R/W
W
W
W
F0803.EPS
1 Adhesion Check
2 Adhesion Level1
3 Adhesion Level2
4 Adhesion Level3
5 Adhesion Level4
6
Adh Measure Value
4 Diagnosis
3 Easy Setup
1 Language
2 PV Damping
3 Base Flow Unit
4 Base Time Unit
5 PV Span
6 Flow Decimal Pnt
7 Total Unit
8 Total Scale
9 Pulse Unit
Pulse Scale
Display Select1
Display Select2
Display Select3
Auto Zero Exe
K10
K11
K12
K13
K14
K15
N10
N30
N31
N32
P
W
W
W
W
W
R
B10/H30
B20/C11
B21/C40
B22/C41
B23/C42
B24/C43
B30/D10
B31/D11
B32/E10
B33/E11
B40/H10
B41/H11
B42/H12
B50/M10
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
u/d
W
W
W
W
W
W
W
W
W
W
W
W
W
W
See
Section 6.5
“Alarm
Functions”
W
––
Parameter
of BRAIN
protocol
Data(*1)
Read/Write
2 Test Mode
3 Test DO
4 Test DIO (O)
5 Test DIO (I)
W
W
W
R
(continued on next page)
Offline
Online
Frequency
Utility
New Configuration
Saved Configuration
1. Device setup
2. PV
3. PV AO
4. PV Span