Owner manual
<8. TECHNICAL DATA>
8-4
IM 01R01B10-00E-E 2nd edition: November 01, 2011-00
All Rights Reserved. Copyright © 2011, Rota Yokogawa
FLOW TABLE WITH METERING TUBE-FLOAT-COMBINATION FOR AIR / GASES
Flow table Suffix code metering tube - oat- combination
Air/Gases 20°C, 1 bar abs Metering tube Float
-x x xx -xx x x x
Max. Flow
[l/h]
Pressure loss
[mbar]
Length
Code
Diameter
Code
Cone
Code
Material
Code
Diameter
Code
Flow
mark
Code
Insertion
Code
1. 9 1 L 6 13
TT A G
N
3 1 L 6 14
4.4 2 L 6 17
6.5 2 L 6 21
10 3 L 6 22
14 4 L 6 23
23 2 L 6 24
PD;TT
B G
33 2 L 6 27
50 2 L 6 31
70 3 L 6 32
100 4 L 6 33
180 3 L 7 34
C G
250 3 L 7 37
400 3 L 7 41
630 4 L 7 42
1000 5 L 7 43
1600 5 L 7 44
D G
2400 10 L 7 47
1600 4 P 0 51
PF
0
6
2500 6 P 0 52
2400 8 P 0 51
PD 7 M
1)
3800 11 P 0 52
6000 6 P 1 53
PD 1 7 M
1)
9300 7 P 1 54
14500 8 P 1 57
23000 10 P 1 61
400 5 P 1 53
PF 1 6 N
6300 5 P 1 54
10000 6 P 1 57
16000 8 P 1 61
35000 11 P 2 62
PD 2 7 M
1)
55000 13 P 2 63
25000 8 P 2 62
PF 2 6 N
40000 10 P 2 63
88000 29 P 4 64
PD 4 7 M
1)
140000 32 P 4 67
220000 34 P 4 71
63000 13 P 4 64
PF 4 6 N
100000 14 P 4 67
160000 17 P 4 71
Description
Length metering tube 300 mm .....................
300 mm .....................
P
L
Diam. metering tube 10 mm to 81 mm .......................... x
Cone metering tube See ow table .................................................. xx
Float material Titanium ...............................................................................
PTFE ....................................................................................
PVDF ...................................................................................
TT
PF
PD
Float diameter 1.6 mm to 54 mm .................................................................................... x
Flow mark For gas .......................................................................................................................
For air ..........................................................................................................................
For air ..........................................................................................................................
G
6
7
Float insertion Without magnet ..............................................................................................................................
With magnet ...................................................................................................................................
N
M
1)
1)
For option limit switch /GM1 to /GM5