Instruction Manual
23
7.1.2. Setting items for every work
START TRQ
Set contents
Selection
Default
Setting the value of start torque to be indicated. Set the value to be as follows:
Upper limit torque ≧ cut torque ≧ lower limit torque ≧ start torque.
0.0~999.0(N・m)
3.0N・m
SWITCH TRQ
Set contents
Selection
Default
Set the torque to switch from motor mid-speed to motor high speed.
0.0~999.0(N・m)
3.0N・m
MIN TRQ
Set contents
Selection
Default
Setting the lower limit of torque. Set the value to be as follows:
Upper limit torque ≧ cut torque ≧ lower limit torque≧ start torque.
0.0~999.0(N・m)
3.0N・m
CUT TRQ
Set contents
Selection
Default
Setting cut torque.
Set the value to be as follows: Upper limit torque ≧ cut torque ≧ lower limit
torque≧ start torque.
0.0~999.0(N・m)
3.0N・m
MAX TRQ
Set contents
Selection
Default
Setting the upper limit torque. Set the value to be as follows:
Upper limit torque ≧ cut torque ≧ lower limit torque≧ start torque.
0.0~999.0(N・m)
3.0N・m
FREERUNNING ANG MIN
Set contents
Selection
Default
Setting the lower limit of free-running angle Set the value to be as follows:
Upper limit of free-running angle ≧ lower limit of free-running angle.
0~30000(°)
0
FREERUNNING ANG MAX
Set contents
Selection
Default
Setting the upper limit of free-running angle. Set the value to be as follows:
Upper limit of free-running angle ≧ lower limit of free-running angle.
0~30000(°)
30000
FINAL ANG MIN
Set contents
Selection
Default
Setting the lower limit of final angle. Set the value to be as follows:
Upper limit of final angle ≧ lower limit of final angle.
0~9999(°)
0