Instruction Manual

23
7.1.2. Setting items for every work
START TRQ
Set contents
Selection
Default
Setting the value of start torque to be indicated. Set the value to be as follows:
Upper limit torque cut torque lower limit torque start torque.
0.0999.0(Nm)
3.0Nm
SWITCH TRQ
Set contents
Selection
Default
Set the torque to switch from motor mid-speed to motor high speed.
0.0999.0(Nm)
3.0Nm
MIN TRQ
Set contents
Selection
Default
Setting the lower limit of torque. Set the value to be as follows:
Upper limit torque cut torque lower limit torque start torque.
0.0999.0(Nm)
3.0Nm
CUT TRQ
Set contents
Selection
Default
Setting cut torque.
Set the value to be as follows: Upper limit torque cut torque lower limit
torque start torque.
0.0999.0(Nm)
3.0Nm
MAX TRQ
Set contents
Selection
Default
Setting the upper limit torque. Set the value to be as follows:
Upper limit torque cut torque lower limit torque start torque.
0.0999.0(Nm)
3.0Nm
FREERUNNING ANG MIN
Set contents
Selection
Default
Setting the lower limit of free-running angle Set the value to be as follows:
Upper limit of free-running angle lower limit of free-running angle.
030000°
0
FREERUNNING ANG MAX
Set contents
Selection
Default
Setting the upper limit of free-running angle. Set the value to be as follows:
Upper limit of free-running angle lower limit of free-running angle.
030000°
30000
FINAL ANG MIN
Set contents
Selection
Default
Setting the lower limit of final angle. Set the value to be as follows:
Upper limit of final angle lower limit of final angle.
09999°
0