Instruction Manual

24
FINAL ANG MAX
Set contents
Selection
Default
Setting the upper limit of final angle. Set the value to be as follows:
Upper limit of final angle lower limit of final angle.
09999°
9999
STOP ABORT TIME
Set contents
Selection
Default
Setting the free running stop abort time.
0.10.5s
0.10
MOTOR LOW SPEED
Set contents
Selection
Default
Setting motor low speed.
12001500(rpm)
1200
MOTOR MIDDLE SPEED
Set contents
Selection
Default
Setting motor middle speed.
15003000(rpm)
2000
MOTOR HIGH SPEED
Set contents
Selection
Default
Setting motor high speed.
15004800(rpm)
3000
JUDGE TIME
Set contents
Selection
Default
Setting judge time.
0.020.99(s)
0.50
BOLT CO-EFFICIENT
Set contents
Selection
Default
Setting bolt coefficient.
0.601.50
1.00
AVERAGE NUM.
Set contents
Selection
Default
Setting average number.
16
3
AVERAGE MODE
Set contents
Selection
Default
Selecting average mode.
CONT: Averaging continuous data
PEAK: Averaging by extracting data for average number from peak value.
CONT
PEAK
CONT
SKIP NUM.
Set contents
Selection
Default
Setting skip number.
05
2