FINAL ANG MAX
Set contents
Selection
Default
Setting the upper limit of final angle. Set the value to be as follows:
Upper limit of final angle ≧ lower limit of final angle.
0~9999(°)
9999
STOP ABORT TIME
Set contents
Selection
Default
Setting the free running stop abort time.
0.1~0.5(s)
0.10
MOTOR LOW SPEED
Set contents
Selection
Default
Setting motor low speed.
1200~1500(rpm)
1200
MOTOR MIDDLE SPEED
Set contents
Selection
Default
Setting motor middle speed.
1500~3000(rpm)
2000
MOTOR HIGH SPEED
Set contents
Selection
Default
Setting motor high speed.
1500~4800(rpm)
3000
JUDGE TIME
Set contents
Selection
Default
Setting judge time.
0.02~0.99(s)
0.50
BOLT CO-EFFICIENT
Set contents
Selection
Default
Setting bolt coefficient.
0.60~1.50
1.00
AVERAGE NUM.
Set contents
Selection
Default
Setting average number.
1~6
3
AVERAGE MODE
Set contents
Selection
Default
Selecting average mode.
CONT: Averaging continuous data
PEAK: Averaging by extracting data for average number from peak value.
CONT
PEAK
CONT
SKIP NUM.
Set contents
Selection
Default
Setting skip number.
0~5
2