036-21508-005-A-0305 ® DESCRIPTION YORK Sunline 2000™ heat pumps are convertible single package units with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame.
036-21508-005-A-0305 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 BELT DRIVE) - SIDE DUCT APPLICATION . . . 22 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . . . 3 10 SUPPLY AIR BLOWER PERFORMANCE (3 - 5 TON DIRECT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . . . 23 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . .
036-21508-005-A-0305 PRODUCT NOMENCLATURE 3-5 Ton Sunline Model Number Nomenclature B Q 048 C00 A 2 A AA 1 Product Generation 1 = First Generation 2 = Second Generation Product Catagory D = Air Cond., Single Package B = Heat Pump, Single Package Product Identifier M = R-22 Standard Efficiency (DCG/DCE) F = R-22 Medium Efficiency (DEG/DEE) H = R-22 High Efficiency (DHG/DHE) Q = R-22 Std.
036-21508-005-A-0305 PRODUCT NOMENCLATURE - Continued 3-6T Sunline Model Number Nomenclature Standard Cabinet AA AB AC AD AE AF AG AH AJ AK AL AM AN AS CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR CS CT CU CV CW CX JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ 4 None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch SS Drain Pan SS Drain Pan & Phase Monitor SS Dra
036-21508-005-A-0305 Standard Cabinet JR JS JT JU JV JW JX HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR HS HT HU HV HW HX NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR NS NT NU NV NW NX TA TB TC Johnson UNT Controller, DFS, APS, Technicoat Evap.
036-21508-005-A-0305 Standard Cabinet TD TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ T1 T3 T4 T6 T7 T9 LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LQ LR LS LT LU LV LW LX WA WB WC WD WE 6 Technicoat Condenser Coil & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Tec
036-21508-005-A-0305 Standard Cabinet WF WG WH WJ WK WL WM WN WP WQ WR WS WT WU WV WW WX Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Evap.
036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet DX EA EB EC ED EE EF EG EH EJ EK EL EM EN EP EQ ER ES ET EU EV EW EX GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GQ GR GS GT GU GV GW GX PA PB 8 CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Phase M
036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond.
036-21508-005-A-0305 Hinged Filter Door & Toolless Access Cabinet QD QE QF QG QH QJ QK QL QM QN QP QQ QR QS QT QU QV QW QX Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond.
036-21508-005-A-0305 FEATURES • All models are available with a wide variety of factorymounted options such as electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guards to make them suitable for almost every application. Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat.
036-21508-005-A-0305 FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.
036-21508-005-A-0305 Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature.
036-21508-005-A-0305 Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. • POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. return air panel.
036-21508-005-A-0305 TABLE 1: SOUND POWER RATING1 UNIT SIZE ESP SOUND POWER (db 10-12 Watts) BLOWER Octave Band Centerline Frequency (Hz) CFM IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 SWL dB(A) dB(A) @ 10Ft.2 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 1.
036-21508-005-A-0305 TABLE 3: BQ036 COOLING CAPACITIES (3 TON) AIR ON EVAPORATOR COIL CFM 1750 1500 1400 1200 1050 900 WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 AIR ON EVAPORATOR COIL CFM 1750 1500 1400 1200 1050 900 WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 TEMPERATURE OF AIR ON CONDENSER COIL 85°F TOTAL CAP.1 MBH INPUT kW 51 46 42 42 49 45 41 41 48 44 40 40 47 41 38 37 45 41 36 36 45 39 35 35 3.4 3.4 3.3 3.3 3.4 3.
036-21508-005-A-0305 TABLE 4: BQ048 COOLING CAPACITIES (4 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 56 53 49 49 55 52 48 48 53 51 47 47 52 49 46 45 50 47 44 44 4.1 4.0 4.0 3.9 4.0 4.0 3.9 3.9 4.0 4.0 3.9 3.9 4.0 3.9 3.8 3.8 3.9 3.9 3.8 3.7 2000 1800 1600 1400 1200 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.
036-21508-005-A-0305 TABLE 5: BQ060 COOLING CAPACITIES (5 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 68 65 61 60 67 64 60 59 66 63 59 58 64 61 57 57 62 59 55 55 5.7 5.6 5.6 5.5 5.6 5.6 5.5 5.5 5.6 5.5 5.4 5.4 5.5 5.5 5.4 5.4 5.5 5.5 5.4 5.3 2500 2250 2000 1750 1500 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.
036-21508-005-A-0305 TABLE 6: BQ HEATING CAPACITIES Model Tonnage CFM RET.
036-21508-005-A-0305 TABLE 7: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 1, 2 UNIT TONNAGE 3 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 0.60 0.40 0.
036-21508-005-A-0305 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 4 1, 2 UNIT TONNAGE 4 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG3 0.60 0.40 0.
036-21508-005-A-0305 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 5 1, 2 UNIT TONNAGE 5 1, 2 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 3 0.60 0.40 0.
036-21508-005-A-0305 TABLE 10: SUPPLY AIR BLOWER PERFORMANCE (3 - 5 TON DIRECT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 4 5 4 5 MOTOR SPEED 1 1 1 UNIT TONNAGE 3 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.20 1 1 0.40 0.50 0.
036-21508-005-A-0305 TABLE 12: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 5-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 ECONOMIZER1, 2 ELECTRIC HEATERS1 BOTTOM DUCT CONNECTIONS1 2600 1.
036-21508-005-A-0305 TABLE 14: ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 4.4 0.0 230-1-60 19.0 105 1.7 4.4 0.0 208-3-60 11.9 85 1.7 4.4 0.0 230-3-60 11.9 85 1.7 4.4 0.0 460-3-60 5.9 42 1.0 2.2 0.0 575-3-60 4.8 34 1 2.2 0.0 208-1-60 25.0 105 2.3 5.0 0.0 230-1-60 25.0 105 2.3 5.0 0.
036-21508-005-A-0305 TABLE 15: ELECTRICAL DATA - BQ060 DIRECT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 6.6 0.0 230-1-60 32.1 148 2.3 6.6 0.0 208-3-60 19.3 137 2.3 6.6 0.0 230-3-60 19.3 137 2.3 6.6 0.0 460-3-60 10.0 62 1.3 3.3 0.0 575-3-60 7.9 50 1.3 3.3 0.0 5 Electric Heater Model No.
036-21508-005-A-0305 TABLE 16: ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Compressors Model Tonnage Voltage RLA Each LRA Each OD Fan ID Blower Motor Motor FLA FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 7.6 0.0 230-1-60 19.0 105 1.7 7.6 0.0 208-3-60 11.9 85 1.7 5.2 0.0 230-3-60 11.9 85 1.7 5.2 0.0 460-3-60 5.9 42 1.0 2.6 0.0 575-3-60 4.8 34 1 2 0.0 208-1-60 25.0 105 2.3 7.6 0.0 230-1-60 25.0 105 2.3 7.6 0.0 208-3-60 14.
036-21508-005-A-0305 TABLE 17: ELECTRICAL DATA - BQ060 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 7.6 0.0 230-1-60 32.1 148 2.3 7.6 0.0 208-3-60 19.3 137 2.3 5.2 0.0 230-3-60 19.3 137 2.3 5.2 0.0 460-3-60 10.0 62 1.3 2.6 0.0 575-3-60 7.9 50 1.3 2 0.0 5 Electric Heater Model No.
036-21508-005-A-0305 TABLE 18: ELECTRICAL DATA - BQ036 & 048 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 4.4 10.0 230-1-60 19.0 105 1.7 4.4 10.0 208-3-60 11.9 85 1.7 4.4 10.0 230-3-60 11.9 85 1.7 4.4 10.0 460-3-60 5.9 42 1.0 2.2 5.0 575-3-60 4.8 34 1 2.2 4.0 208-1-60 25.0 105 2.3 5.0 10.0 230-1-60 25.0 105 2.3 5.0 10.
036-21508-005-A-0305 TABLE 19: ELECTRICAL DATA - BQ060 DIRECT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 6.6 10.0 230-1-60 32.1 148 2.3 6.6 10.0 208-3-60 19.3 137 2.3 6.6 10.0 230-3-60 19.3 137 2.3 6.6 10.0 460-3-60 10.0 62 1.3 3.3 5.0 575-3-60 7.9 50 1.3 3.3 4.0 5 Electric Heater Model No.
036-21508-005-A-0305 TABLE 20: ELECTRICAL DATA - BQ036 & 048 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 19.0 105 1.7 7.6 10.0 230-1-60 19.0 105 1.7 7.6 10.0 208-3-60 11.9 85 1.7 5.2 10.0 230-3-60 11.9 85 1.7 5.2 10.0 460-3-60 5.9 42 1.0 2.6 5.0 575-3-60 4.8 34 1 2 4.0 208-1-60 25.0 105 2.3 7.6 10.0 230-1-60 25.0 105 2.3 7.6 10.
036-21508-005-A-0305 TABLE 21: ELECTRICAL DATA - BQ060 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET Model Tonnage Compressors Voltage RLA Each LRA Each OD Fan Motor FLA ID Blower Motor FLA Conv Outlet Amps 208-1-60 32.1 148 2.3 7.6 10.0 230-1-60 32.1 148 2.3 7.6 10.0 208-3-60 19.3 137 2.3 5.2 10.0 230-3-60 19.3 137 2.3 5.2 10.0 460-3-60 10.0 62 1.3 2.6 5.0 575-3-60 7.9 50 1.3 2 4.0 5 Electric Heater Model No.
036-21508-005-A-0305 TABLE 22: PHYSICAL DATA BQ MODELS Centrifugal Blower (Dia. x Wd. in.) EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FANS CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE 12 X 10 12 X 10 1/2 3/4 1 1 1/2 1 1/2 1 1/2 Rows Deep 4 3 3 Fins Per Inch 16 15 15 Face Area (Sq. Ft.) 4.3 5.1 5.1 Propeller Dia. (in.) 22 22 24 Fan Motor Hp 1/3 1/2 1/2 4500 Nom. CFM 4300 4200 Rows Deep 1 1 1 Fins Per Inch 20 20 20 Face Area (Sq. Ft.) 17.1 17.
036-21508-005-A-0305 TYPICAL POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTECTION AND WIRING. TYPICAL CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT 1 TERMINALS ADD JUMPER RH UNIT TERMINAL STRIP TB1 RC R Y Y1 24 VOLT TRANSFORMER Y2 W W1 W2 G G C 1 24 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024.
036-21508-005-A-0305 FIGURE 3 - UNIT DIMENSIONS (3 - 5 TON HEAT PUMP) FRONT VIEW DETAIL “A” FIGURE 4 - UNIT WITH ECONOMIZER RAINHOOD Unitary Products Group 35
036-21508-005-A-0305 DETAIL “B” FIGURE 5 - UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD FIGURE 6 - UNIT DIMENSIONS (REAR VIEW) 36 Unitary Products Group
036-21508-005-A-0305 FILTER ACCESS BLOWER MOTOR ACCESS DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) A,B WIRING ENTRY (See Detail “B”) CONTROL BOX ACCESS DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH “BELT-DRIVE” OPTION FIGURE 7 - DISCONNECT/BLOWER ACCESS LOCATION TABLE 25: UTILITIES ENTRY HOLE OPENING SIZE (DIA.
036-21508-005-A-0305 FIGURE 8 - 38 TYPICAL APPLICATIONS Unitary Products Group
036-21508-005-A-0305 BACK OF UNIT A 447/8 BACK OF UNIT A 447/8 821/4 821/4 D B F X X B APPROXIMATE CENTER OF GRAVITY FIGURE 9 - CONDENSER COIL END OF UNIT C Y FRONT OF UNIT C E APPROXIMATE CENTER OF GRAVITY D Y FRONT OF UNIT CONDENSER COIL END OF UNIT FOUR AND SIX POINT LOADING TABLE 27: BQ 4 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL A B C D BQ036 628 139 137 174 177 BQ048 668 148 146 185 189 BQ060 693 154 151 192 196 TABLE 28: BQ 6 POINT LOADS WEIGHT DISTRIBUT
036-21508-005-A-0305 FIGURE 10 - ROOF CURB DIMENSIONS GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. York's Sunline 2000TM units are convertible single package heat pumps. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof.
036-21508-005-A-0305 lated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications.
036-21508-005-A-0305 matic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). • UNIT OPERATING CHARACTERISTICS a. Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240.
036-21508-005-A-0305 • BAS CONTROLS (SImplicity™ INTELLI-Comfort™, CPC, JOHNSON, HONEYWELL, NOVAR) • BAS READY ECONOMIZER (BELIMO ACTUATOR WITHOUT A CONTROLLER) • HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS • • BOTTOM DRAIN CONNECTION • 2" PLEATED FILTERS • DISCONNECT SWITCH • SUPPLY AIR SMOKE DETECTOR • RETURN AIR SMOKE DETECTOR STAINLESS STEEL DRAIN PAN Unitary Products Group 43
Subject to change without notice. Printed in U.S.A. Copyright © 2005 by Unitary Products Group. All rights reserved.