Technical Guide

718444-YTG-F-0214
12 Johnson Controls Unitary Products
DNX Single Stage Gas Heat
Component
Models
DNX024 DNX036 DNX048
Nominal Tonnage 2.0 3.0 4.0
AHRI COOLING PERFORMANCE
Gross Capacity @ AHRI A point (MBH) 24.6 38.4 50.0
AHRI net capacity (MBH) 24.0 37.0 48.0
EER 11.5 12.3 11.2
SEER 15.0 16.5 15.0
Nominal CFM 800 1275 1550
System power (KW) 2.1 3.0 4.3
Refrigerant type R-410A R-410A R-410A
Refrigerant charge (lb-oz) 7-8 9-12 9-8
AHRI HEATING PERFORMANCE
Heating model N036 N056 N065 N090 N065 N090 N110
Heat input (K Btu) 45 70 80 108 80 108 135
Heat output (K Btu) 36 56 64 87 64 87 108
AFUE % 81.0 81.0 81.0 81.0 81.0 81.0 81.0
No. burners 2334345
No. stages 1111111
Temperature Rise Range (ºF) 25-55 30-60 25-55 45-75 25-55 35-65 45-75
Max. Outlet Air Temp. (ºF) 165 175 165 175 165 175 175
Gas Limit Setting (ºF) 140 160 140 160 150 170 160
Gas piping connection (in.) 1/2 1/2 1/2
DIMENSIONS (inches)
Length 49 1/8 49 1/8 49 1/8
Width 47 1/4 47 1/4 47 1/4
Height 33 1/2 41 1/2 41 1/2
OPERATING WT. (lbs.)
Unit Weight (lbs.) 440 480 500
COMPRESSOR
Type Scroll 2-spd Scroll 2-spd Scroll 2-spd
CONDENSER COIL DATA
Face area (Sq. Ft.) 11.7 14.7 14.7
Rows 2 2 2
Fins per inch 20 20 20
Tube diameter (in.) 3/8 3/8 3/8
Circuitry Type Interlaced Interlaced Interlaced
EVAPORATOR COIL DATA
Face area (Sq. Ft.) 3.4 4.4 4.4
Rows 2 3 3
Fins per inch 15 16 16
Tube diameter 3/8 3/8 3/8
Circuitry Type Interlaced Interlaced Interlaced
Refrigerant control TXV TXV TXV
CONDENSER FAN DATA
Fan diameter (Inch) 22 22 22
Type Prop Prop Prop
Drive type Direct Direct Direct
No. speeds 1 2 2
Motor HP 1/4 1/3 1/3
RPM 1100 900/1100 900/1100
Nominal total CFM 2400 2400 3000
DIRECT DRIVE EVAP FAN DATA
Fan Size (Inch) 10 x 8 11 x 10 11 x 10
Type Centrifugal Centrifugal Centrifugal
Motor HP 1/2 1 1
RPM Variable Variable Variable
Frame size 48 48 48
FILTERS
Quantity - Size 1 - 20 x 20 x 1 2 - 20 x 12 x 1 2 - 20 x 12 x 1