Specifications
Table Of Contents
- Form 150.72-NM1 (908)
- GENERAL SAFETY GUIDELINES
- CHANGEABILITY OF THIS DOCUMENT
- TABLE OF CONTENTS
- LIST OF FIGURES
- LIST OF TABLES
- SECTION 1 – GENERAL CHILLER INFORMATION & SAFETY
- SECTION 2 – PRODUCT DESCRIPTION
- INTRODUCTION
- GENERAL SYSTEM DESCRIPTION
- HIGH AMBIENT KIT
- BUILDING AUTOMATION SYSTEM INTERFACE
- MILLENIUM CONTROL CENTER
- POWER PANEL
- ACCESSORIES AND OPTIONS
- UNIT COMPONENTS
- CONTROL / POWER PANEL COMPONENTS
- PRODUCT IDENTIFICATION NUMBER (PIN)
- BASIC UNIT NOMENCLATURE
- REFRIGERANT FLOW DIAGRAM
- PROCESS AND INSTRUMENTATION DIAGRAM
- SECTION 3 – HANDLING AND STORAGE
- SECTION 4 – INSTALLATION
- INSTALLATION CHECKLIST
- HANDLING
- INSPECTION
- LOCATION AND CLEARANCES
- SPRING ISOLATORS (OPTIONAL)
- COMPRESSOR MOUNTING
- REMOTE COOLER OPTION
- CHILLED LIQUID PIPING
- PIPEWORK ARRANGEMENT
- DUCT WORK CONNECTION
- WIRING
- COMPRESSOR HEATERS
- RELIEF VALVES
- HIGH PRESSURE CUTOUT
- SINGLE-POINT SUPPLY CONNECTION – TERMINAL BLOCK, NON-FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER
- USER CONTROL WIRING INPUTS
- USER CONTROL WIRING OUTPUTS
- SECTION 5 – TECHNICAL DATA
- OPERATIONAL LIMITATIONS (ENGLISH)
- HEAT EXCHANGER FLOW, GPM
- PHYSICAL DATA (ENGLISH)
- ELECTRICAL DATA
- ELECTRICAL NOTES
- ELECTRICAL DATA W/O PUMPS
- ELECTRICAL DATA W/ PUMPS
- ELECTRICAL NOTES AND LEGEND
- WIRING DIAGRAMS
- DIMENSIONS (ENGLISH)
- TECHNICAL DATA – CLEARANCES
- WEIGHT DISTRIBUTION AND ISOLATOR MOUNTING POSITIONS
- ISOLATOR INFORMATION FOR UNITS SHIPPED ON OR AFTER JUNE 15, 2008
- ISOLATOR INFORMATION FOR UNITS SHIPPED BEFORE JUNE 15, 2008
- SLRS Seismic Isolator Specifications
- SLRS Seismic Isolator Installation and Adjustment
- One Inch Deflection Spring Isolator Cross-reference
- Installation of 1” Deflection Mounts
- Neoprene Isolator Cross-reference
- Two Inch Deflection, Seismic Spring IsolatorCross-reference - SLRS
- SLRS Seismic Isolator Installation and Adjustment
- SECTION 6 – COMMISSIONING
- SECTION 7 – UNIT CONTROLS
- SECTION 8 – UNIT OPERATION
- CAPACITY CONTROL
- SUCTION PRESSURE LIMIT CONTROLS
- DISCHARGE PRESSURE LIMIT CONTROLS
- LEAVING CHILLED LIQUID CONTROL
- LEAVING CHILLED LIQUID CONTROLOVERRIDE TO REDUCE CYCLING
- LEAVING CHILLED LIQUID SYSTEM LEAD/LAG AND COMPRESSOR SEQUENCING
- RETURN CHILLED LIQUID CONTROL
- RETURN CHILLLED LIQUID SYSTEM LEAD/LAG AND COMPRESSOR SEQUENCING
- ANTI-RECYCLE TIMER
- ANTI-COINCIDENCE TIMER
- EVAPORATOR PUMP CONTROL & YORK HYDRO KIT PUMP CONTROL
- EVAPORATOR HEATER CONTROL
- PUMPDOWN CONTROL
- STANDARD CONDENSER FAN CONTROL
- LOAD LIMITING
- COMPRESSOR RUN STATUS
- ALARM STATUS
- REMOTE BAS/EMS TEMPERATURE RESET USINGA VOLTAGE OR CURRENT SIGNAL
- SECTION 9 – SERVICE AND TROUBLESHOOTING
- SECTION 10 – MAINTENANCE
![](/manual/york/millennium-y14/specifications-english/images/img-117.png)
JOHNSON CONTROLS
126
FORM 150.72-NM1 (908)
Unit Controls
Displays the programmed Low Ambient Cutout.
Di sp lays the Leaving Liqu id Temp. C ut out
programmed.
Displays the programmed Fan On Pressure.
Displays the programmed Fan Off Differential.
Displays the programmed High Current Trip Voltage.
Displays the programmed High Current Trip Voltage.
Indicates the Pump Control option is selected.
Displays the Leaving and Return chilled Liquid
Temperature at the time of the fault.
Displays the programmed Setpoint and Range, if
the chiller is programmed for leaving chilled liquid
control.
Displays the programmed Setpoint and Range, if the
chiller is programmed for return chilled liquid control.
Displays the Ambient Temp. at the time of the fault.
Displays the type of Ambient Control; Standard or Low
Ambient.
Displays Local or Remote control selection.
Displays the type of chilled liquid control; Leaving or
Return.
Displays the type of lead/lag control; Manual System 1,
Manual System 2 or Automatic. This is only selectable
on 2-system chillers.
Displays the type of fan control; Discharge Pressure or
Ambient and Discharge Pressure.
Displays whether Manual Override was Enabled or
Disabled.
Displays type of Current Feedback utilized.
Displays whether the optional European Soft Start was
installed and selected.
Displays the programmed Discharge Pressure Cutout.
Displays the programmed Suction Pressure Cutout.
L O W A M B I E N T T E M P
C U T O U T = X X X . X ° F
S U C T I O N P R E S S U R E
C U T O U T = X X X X P S I G
D I S C H A R G E P R E S S U R E
C U T O U T = X X X X P S I G
L E A D / L A G C O N T R O L
X X X X X X X X
L O C A L / R E M O T E M O D E
X X X X X X X X X
A M B I E N T C O N T R O L
X X X X X X X X X X
L E A V I N G L I Q U I D T E M P
C U T O U T = X X X . X ° F
M A N U A L O V E R R I D E M O D E
X X X X X X X X X
C O N T R O L M O D E
L E A V I N G L I Q U I D
F A N C O N T R O L
D I S C H A R G E P R E S S U R E
F A N C O N T R O L O N
P R E S S U R E = X X X P S I G
C U R R E N T F E E D B A C K
X X X X X X X X X X X X X X X X
S O F T S T A R T
X X X X X X X
F A N D I F F E R E N T I A L O F F
P R E S S U R E = P S I G
S Y S 2 T R I P V O L T S
= X . X V O L T S
S Y S 1 T R I P V O L T S
= X . X V O L T S
S E T P O I N T = X X X . X ° F
R A N G E = + / - ° F
A M B I E N T A I R T E M P
= X X X . X ° F
L C H L T = X X X . X ° F
R C H L T = X X X . X ° F
S E T P O I N T = X X X . X ° F
R A N G E = + X X . X ° F
Y O R K H Y D R O
K I T P U M P S = X